Use And Care Manual
31
OPERATION
WARNING: Do not allow fans to blow directly into the heater. Avoid any drafts that alter burner
ame patterns.
WARNING: Do not use a blower insert, heat exchanger insert or other acessory not approved for
use with this heater.
INSPECTING BURNERS
Check pilot ame pattern and burner ame patterns often.
PILOT FLAME PATTERN
Figure 29 shows a correct pilot ame pattern. Figure 30 shows an incorrect pilot ame pattern. The
incorrect pilot ame is not touching the thermocouple. This will cause the thermocouple to cool. When
the thermocouple cools, the heater will shut down.
If pilot ame pattern is incorrect, as shown in Figure 30.
• turn heater o (see To Turn O Gas to Appliance, page 24.
• see Troubleshooting, page 34.
Fig. 29 - Correct Pilot Flame Pattern Fig. 30 - Incorrect Pilot Flame Pattern
NG
LP
NG
LP
A
LP PILOT
A
LP PILOT
A
NG PILOT
A
NG PILOT