User's Guide
PLM150 User’s Guide (LoRaWAN) V1.0
8
Copyright © 2018 PLNetworks
The information contained herein is the property of PLNetworks and is provided without liability of errors,
omissions, and mistakes. No part may be reproduced or copied without written permission or contract.
[ Table 6 System Command ]
Command
Function
Description
+HELP
Help
List the AT Commands that PLM150 supports.
+SHOW
Show
Return the current configuration setting values.
+RSET
PLM150 reset
Reboot PLM150. Rebooting will take 2 to 3
seconds after issuing the command.
+SLEP
+SLEP=<sec>
Sleep Mode
Put the system to low-power (Sleep) mode for the
specified number of seconds.
Note: AT commands via Console, data sending and
receiving will not be executed during the specified
sleep time.
+GEUI
Serial number
Return PLM150 Serial Number(EUI). Read-only
+BATT
Power Voltage
Returns the Voltage value of input power. If a
battery is used, the battery power level value will
be returned.
+CBAR
+CBAR=<baudrate>
Console
Baudrate
Configure UART baud rate to the host.
Supporting baud rate: 9600, 19200, 38400, 57600,
115200
<Default Value> : 115200
+UBAR
+UBAR=<baudrate>
User UART
Baudrate
Configure UART baud rate for a sensor interface
(in the event of connecting any sensors).
Supporting baud rate: 9600, 19200, 38400, 57600,
115200
<Default Value> : 9600
+ECHO
+ECHO=1 or 0
Console Echo
mode
Console UART Echo mode
(1: enable, 0:disable)