Operation Manual

12 | English
Important information!
The existing boiler wires that connect
the boiler to the thermostat have to be
connected to the on/ off connection
(0-230V, max. 5A) of the boiler. You can
nd this information in the manual of
your boiler
The boiler wires that connect the boiler
to the thermostat, must at least be
cable type H05VVH2-F 2x1.0 mm²,
cannot be longer than 50 metres and
must not have a greater resistance
than 5 Ohm per wire. If this is the case
however, we advise you to have the
wires replaced.
Check beforehand the availability and
quality of the network connection and
check also if a free power outlet is
available near the boiler.
Make sure you have the password
of the WiFi network to which you will
connect Anna.
Pull out the plug of the boiler before
you continue. Follow the safety
regulations.
Do not connect Anna directly to 230V
or directly to the boiler. This can cause
permanent damage to Anna.
The installation.
Smartphone or tablet
Smile T230 AnnaBoiler
2-pole switch contact -
on/off (0-230V, max 5A)
Additional power outlet
near the boiler
 n cnect Anna
directly  230V 
directly   .
Penal- ctact r
cnec   hng
syem (230V, 5A max).
Network router
Exng r
(H05VVH2-F 2x1.0 mm²)