User manual

Tube Replacement
WEEE Compliance No. 01576542
Starter Replacement
SPECIFICATION / REPLACEMENT PARTS
Unit PL30 White
Voltage 230V ~ 50Hz
Dimensions(mm) 470 x 285 x 90
Coverage 80 Sq. Meters
Weight 4 Kg
Light Output 30W
Tubes 2 x TP15-18
Starter 2 x I154
Glueboards (x6) INF309
Unit PL60 S/S
Voltage 230V ~ 50Hz
Dimensions(mm) 470 x 330 x 130
Coverage 160 Sq. Meters
Weight 7 Kg
Light Output 60W
Tubes 4 x TP15-18
Starter 4 x I154
Glueboards (x6) INF309
Glueboard Replacement
R4 06/10
C
2010
P+L Systems Ltd
Information provided on these instructions is modified and
updated from time to time. This is due to the constant
redevelopment of our products. As such, it is not intended that
you should rely on it or that it should form part of any contract.
P+L Systems Ltd
Ten St James Business Park
Grimbald Crag Court
Knaresborough
HG5 8QB UK
T +44 (0)800 988 5359
F +44 (0)1423 863 497
W www.pandlsystems.com
E info@pandlsystems.com
GLUEBOARD REPLACEMENT
GLUEBOARD REPLACEMENT SHOULD BE CARRIED OUT BY SERVICE PERSONNEL ONLY, AFTER
ENSURING THAT THE UNIT IS DISCONNECTED FROM THE MAINS SUPPLY.
The glueboard should be replaced every month with a genuine glupac
®
glueboard. Use of
non-approved glueboards may invalidate your guarantee. PlusLight
comes supplied with
discreet black glueboards with printed grids for simple insect evaluation and monitoring.
To replace the glueboard…
PlusLight
30
1. Remove the mains cable from your PlusLight
.
2. Swing open the front guard until it rests open against the fixing surface.
3. Remove the used glupac
®
glueboard by simply releasing from the metal chassis
and either retain for catch evaluation or dispose of it hygienically.
4. Remove the protective release paper from the new glupac
®
glueboard.
5. Carefully position the new glupac
®
glueboard into position with the adhesive side
facing the tubes, ensuring the glueboard is held in position by the metal clips at the
top of the metal chassis.
PlusLight
60
1. Swing open the front guard until it is held in position by the aluminium clips.
2. Remove the used glupac
®
glueboard by simply releasing from the metal chassis and
either retain for catch evaluation or dispose of it hygienically.
3. Remove the protective release paper from the new glupac
®
glueboard.
4. Carefully position the new glupac
®
glueboard into position with the adhesive side facing
the tubes, ensuring the glueboard is held in position by the metal clips at the top of the
metal chassis.
5. Release the front guard by pulling the aluminium clips away from the chassis.
Always ensure the selected genuine glupac
®
glueboards are compatible with your unit, available
from your PCO or P+L Systems Ltd.
TUBE REPLACEMENT
TUBE REPLACEMENT SHOULD BE CARRIED OUT BY SERVICE PERSONNEL ONLY, AFTER ENSURING THAT
THE UNIT IS DISCONNECTED FROM THE MAINS SUPPLY.
To ensure the efficiency of PlusLight
in catching flying insects, the UV tubes should be replaced
annually. After twelve months the phosphor coating that emits the correct wavelength of UV light
has burnt away and the UV output is diminished substantially.
To replace the UV tubes…
1. Rotate the tube through 90°, freeing it from the tube holders.
2. Pull the tube away from the chassis.
3. Dispose of the used UV tube in conjunction with local WEEE regulations.
STARTER REPLACEMENT
STARTER REPLACEMENT SHOULD BE CARRIED OUT BY SERVICE PERSONNEL ONLY, AFTER ENSURING
THAT THE UNIT IS DISCONNECTED FROM THE MAINS SUPPLY.
The starters provide an extra spark to initially light the UV tube. Starters wear out and should be
replaced at the same intervals as the UV tubes.
To replace the starters…
1. Rotate the starter anti-clockwise.
2. Pull the starter free from the unit.