Instruction Manual
Users Guide: iMFD Sensor Module 
Version 1.0 March 14, 2008 
Version 1.0 March 14, 2008 
www.plxdevices.com
(408)745-7591 
iMFD Sensor Module SM-Fluid Pressure 
*Please read the instructions completely through at least once before proceeding with the 
installation to minimize errors. 
*DO NOT use this sensor for Fuel Pressure sensing purpose 
*Double check polarity of power before powering it on for the first time. 
Overview: 
 (Figure 1)  (Figure 2) 
1.  Connects to 12V-18V power source. 
2.  Analog outputs (0-5V linear output) *For sensor #1 ONLY 
3.  Termination jumper. Closed for first SM in iMFD daisy chain. 
4.  Connects to next SM in iMFD daisy chain or to first DM 
5.  Connects to previous SM or unconnected if first SM in iMFD daisy chain 
6.  Connects to PLX Fluid Pressure Sensor. Up to 2 sensors can be connected for 2 channel operation. 
7.  Fluid Pressure Sensor (150psi). (*Using a sensor not provided by PLX Devices may lead to inaccurate readings due to a 
mismatch in calibration) 
8.  24k Gold Ring Terminal 
9.  Molex Connector Terminals 
10.  Molex 2 Pin Connector 
Install the Fluid Pressure Sensor: 
1.  The PLX Fluid Pressure probe screws into a 1/8 NPT tap. 
2.  Connect the fluid pressure sensor with the provided 2 pin Molex connector according to the following diagram. It should 
connect to the port “G” on the sensor. Connections can be made by crimping the terminals or soldering the terminals 
with the provided wire. *Note the orientation of the Molex 2 pin connector. A reverse connection will result in inaccurate 
readings and may damage the device. 