Installation Guide

horizontal panel installation
PANELS INTERSECTING AT OPENINGS –
BOTTOM OF WINDOWS
First, you will need to determine the width of the window or opening.
Position the panel in place against the window. Then, mark the panel
where it needs to be cut on both sides of the opening. Next, determine
how deep to cut the panel by measuring from the nail ange of the
previous row of siding to 1/4" from the bottom of the windowsill. Fi-
nally, making sure to measure it from the bottom, mark the measured
distance to be trimmed onto the panel to be cut (FIG 13.1). Undersill
trim must be used under all windows.
PANELS INTERSECTING AT OPENINGS –
TOPS OF DOORS AND WINDOWS
You will cut the panels to t around the tops of doors and windows
the same as you did for the bottom of the window (FIG 13.2). First
place the panel and mark the width of the opening, then measure from
the bottom of the nail ange of the previous row of siding to a 1/4"
above the top of the window. Mark the panel to be trimmed with this
measured distance from the panel bottom.
UNDERSILL AND UNDEREAVE SHIMS
Shims may be needed to keep the angle of the last course consistent
in the eaves. Shims should be nailed behind the utility trim that will
be receiving the cut end of the panels (FIG 13.3). This may also be
needed with the piece below the windows. Shims can be wood or
foam sheathing.
FINAL ROW OF SIDING IN THE EAVE
The nal row of siding under an eave will likely need trimming to t
(FIG 13.4). To do this, measure from the nail ange of the previous
row of siding to 1/4" from the eave. Mark this line on the nal panel
and trim. You can install a J-channel and a utility trim or just a utility
trim in the eave area to receive the last cut course of siding. Check to
see if shims are needed to keep slope angle correct. If needed, install
shims. Install utility trim ush with the eave along the entire length
of the wall. The siding can then be inserted into the utility trim and
locked into the lower row of siding.
FIG 13.4
FIG 13.1
J-CHANNEL
UNDERSILL
TRIM
SNAPLOCK
LUGS
FIG 13.2
FIG 13.3
SHIM
UTILITY
TRIM
SIDING
J-CHANNEL
61
steel siding installation