Datasheet

High voltage probes 5 mm
High impedance passive probes
ELFA part no. Probe model Recommended System Rise time Attenuation Load Rated voltage Cable length
scope bandwidth bandwidth
up to (-3 dB) CAT II
76-xxx-xx PHV 1000 500 MHz 400 MHz 0.9 ns 100:1 50M / 7.5 pF 1000 V * 2 m
860-622-A00
76-xxx-xx PHV 1000-C 500 MHz 400 MHz 0.9 ns 100:1 50M / 7.5 pF 1000 V * 2 m
86C-622-A00
76-xxx-xx PHV 1000-C-RO 500 MHz 400 MHz 0.9 ns 100:1 50 M / 7.5 pF 1000 V * 2 m
86C-622-A02
76-xxx-xx PHV 1000-3-C 500 MHz 250 MHz 1.4 ns 100:1 50M / 7.5 pF 1000 V * 3 m
86C-623-A00
76-xxx-xx PHV 1000-3-C-RO 500 MHz 250 MHz 1.4 ns 100:1 50 M / 7.5 pF 1000 V * 3 m
86C-623-A02
PMK passive probes feature CeramCore
TM
technology – high quality ceramic hybric core
RO suffix indicates ReadOut capability enabling automatic attenuation scaling with scopes
which support this feature.
C suffix models are shipped with a case including additional accessories:
BNC adapter 5.0-L, a set of coding rings (3 x 4 colors), flexible adapter 5.0-L,
ground lead 22 cm to 4 mm banana plug and safety alligator clip (red)
* Measurement category I: 1000 VAC rms or VDC, 4000 V transient overvoltage

Summary of content (1 pages)