Datasheet

21
8000
6000
4000
2000
0
PHV1000 RMS versus Peak Pulse
Measurement Category I
AC rms or DC
[V]
Peak Pulse [V]
0 200 400 600 800 1000
Model
Order-No.
Attenuation (*)
Input Impedance
Input Coupling of the Measuring Instrument
System Bandwidth (-3 dB)
Risetime (10% - 90 %)
Compensation Range (**)
Rated Voltage
Measurement category I
Measurement category II
Pollution Degree
Safety Standard (IEC / EN)
Cable Length (***)
(*) Further attenuations on request
(**) other compensation ranges on request
(***) other cable lengths on request
The probe is suitable for pulse measurements of up to 6 kV in measure-
ment category I. AC or DC voltage up to 1 kV may have a maximum of
4 kV transient overvoltage.
PHV 1000-RO
860-622-A02
100:1
50 MΩ
7.5 pF
1 MΩ AC/DC
400 MHz
0.9 nsec
10 – 50 pF
1000 V AC eff. or DC
4000 V trans. overvoltage
1000 V CAT II
2
61010-031
2 m
PHV 1000-3-RO
860-623-A02
100:1
50 MΩ
7.5 pF
1 MΩ AC/DC
250 MHz
1.4 nsec
10 – 50 pF
1000 V AC eff. or DC
4000 V trans. overvoltage
1000 V CAT II
2
61010-031
3 m
PHVS 1000-RO
860-722-A03
1000:1
50 MΩ
7.5 pF
1 MΩ AC/DC
400 MHz
0.9 nsec
10 – 50 pF
1000 V AC eff. or DC
4000 V trans. overvoltage
1000 V CAT II
2
61010-031
2 m
PHV High Z Probes
Scope of Delivery PHV Series
nProbe
nSpring Tip 0.8 mm
nInsulating Cap 5.0-L
nGround Lead 22 cm
nAdjustment Tool T
nSolid Tip 0.8 mm
nSprung Hook 5.0-L
nProtection Cap 5.0-L
Options
nAdditional silicone cable insulation and/or reinforced strain relief
available..
nDelivery in carry case including standard and additional accessories:
- BNC Adapter 5.0-L
- Flexible Adapter 5.0-L
- Coding Rings (Set) 3 x 4 Colors
- Ground Lead 22 cm to 4 mm banana plug
- Safety Alligator Clip red