PS0, PS1, and PS2 – Period Select 
Selects the division ratio applied to the L/R oscillator output to set the period being measured
. 
Table 11: Period Select 
PS2  PS1  PS0  Ratio 
0  0  0  /32 
0  0  1  /64 
0  1  0  /128 
0  1  1  /256 
1  0  0  /512 
1  0  1  /1024 
1  1  0  /2048 
1  1  1  /4096 
ODIR – Oscillator Direction 
Determines the magnetic oscillator direction if MOT is set to 1. It has no effect on direction when the MOT 
bit is set to zero. This is used for debug purposes only, and will not be set in normal operation. 
MOT – Magnetic Oscillator Test 
When set, causes the magnetic oscillator selected by AS0 and AS1, in the directions selected by ODIR to 
run continuously until PNI ASIC is reset. 
ASO & ASI – Axis Select 
Determines which axis is being measured. 
NOTE
When 2 MHz scaling is selected, the magnetic sensor oscillator does not run. Instead, the internal 
2 MHz oscillator is turned on. The 2 MHz clock cycles are counted until a command byte is sent 
disabling the scaling function. A RESET stops the 2 MHz oscillator and clears all bits. 
Table 12: ASO and ASI Axis Select 
Function  AS1  AS0 
2 MHz scaling  0  0 
X axis  0  1 
Y axis  1  0 
Z axis  1  1 