Instruction Manual
MicroMag User Manual – March 2010  Page 17 of 23 
Table 4-2: Maximum Delay for DRDY 
Period Select 
Maximum Delay 
32 
500 μS 
64 
1.0 mS 
128 
2.0 mS 
256 
4.0 mS 
512 
7.5 mS 
1024 
15 mS 
2048 
35.5 mS 
4096 
60 mS 
4.3.6  RESET (Reset) 
RESET must be toggled from LOW-HIGH-LOW before sending a measurement 
command. RESET is usually LOW. 
4.3.7  VDD (DC Voltage Input) 
It is recommended the user supply 3.0 VDC on this line, in part because the bias 
resistor values on the MicroMag module were optimized for 3.0 VDC operation. 
However, the MicroMag can be run at other voltages within the specification. 
While not necessary, if the MicroMag will be run at some other voltage it may be 
desirable to change the bias resistors for better performance.  Refer to the PNI ASIC 
User Manual for bias resistor values for other operating voltages. The resistors to be 
changed are labeled R1, R2, R3, R4, R6, & R7. 
4.3.8  COMP (Comparator) 
COMP is only available on the MicroMag2 and it provides the output signal from 
the comparator component built into the PNI ASIC. This is used for diagnostics. 
4.3.9  DHST (Clock Output) 
DHST is only available on the MicroMag2 and it outputs the ASIC’s high speed 
clock, but at half the speed. This is used for diagnostics. 