Instruction Manual
PNI Sensor Corporation  DOC# 1015175 r01 
MicroMag User Manual – March 2010  Page 6 of 23 
3  Specifications 
3.1  Module Characteristics 
Table 3-1: Absolute Maximum Ratings 
Parameter 
Symbol 
Maximum 
Units 
DC Supply Voltage 
V
DD
5.25 
VDC 
Input Pin Voltage 
V
IN
V
DD
 + 0.3 
VDC 
Input Pin Current @ 25C 
I
IN
10 mA 
mA 
Storage Temperature 
T
STRG
+85 
C 
CAUTION: 
Stresses beyond those listed in Table 3-1 may cause permanent damage to the 
device. These are stress ratings only. Functional operation of the device at these or 
any other conditions beyond those indicated in the operational sections of the 
specifications is not implied. Exposure to absolute maximum rating conditions for 
extended periods may affect device reliability. 
Table 3-2: Module Operating Characteristic 
Parameter 
Value 
Units 
Field Measurement Range
1
-1100 to +1100 
T 
Gain
2
31.24 
counts/ T 
Resolution
2
 (1/Gain) 
0.03 
T 
Linearity, ± 300 µT 
0.6 
% 
DC Supply Voltage (V
DD
) 
3.0 nominal 
2.2 to 5.0 allowable 
VDC 
Idle Current
3
< 0.1 
mA rms 
Continuous Current
3
0.5 
mA rms 
Sensor Frequency
3,4
175 
kHz 
Operating Temperature 
-20 to +70 
C 
Notes: 
1)  Field Measurement Range is defined as the monotonic region of the output characteristic curve. 
2)  Period  select  value  of  2048.    The  Gain  and  Resolution  can  be  increased  by  a  factor  of  2 by 
setting the period select to 4095.  However, the ASIC counter can overflow if the field is strong 
enough to drive the count beyond a signed 16-bit signed integer.  Period select set to 2048 is the 
highest  setting  where  it  is  impossible  to  overflow  the  counter.    In  practical  magnetometer 