Manual
PoBlocks user manual (March 31, 2014)
15
www.poscope.com
In order to connect multiple inputs (left ports) to one output (right port), start by creating a base
connection between one input and one output. Then, start adding another connection by clicking on an
empty input and complete the connection by clicking on an existing connection.
8.6. Constant inputs
Often a simple constant value is used as an input parameter. In order to insert a constant value, right
click on an empty input (left port) - constants can not be added to output (right ports). An default
constant value 0 appears - to edit the value, just click on it and enter a new value. To replace the
constant with a connection, simply drop the new connection to the port, containing the constant value -
the constant value will be replaced by the newly established connection.
8.7. Removing connections
In order to remove an existing connection, select the connection by clicking on it and press 'Delete'
button.
8.8. Configuring blocks
Basic blocks are configured using the properties panel on the right of the design area. Select a block first
and the properties panel will be automatically populated with options for that block. Help for each
property is included in the block help pop-up window in the block library.
Advanced (extended) blocks (those that have light blue background) like Event drum, Look-up table,
Schedule, LCD UI, Custom PoIL, etc. have a dedicated block properties editor. This editor is accessed by
double-clicking on a block. The description of each of these blocks can be found in the blocks section
below.