Manual

PoBlocks user manual (March 31, 2014)
33
www.poscope.com
Initial value (Integer, 0 to 65535): The initial value of the retained block after it gets
uploaded to the device.
Initial RAM value (Integer, 0 to 65535): The initial value of the retained block after it
gets uploaded to the device.
Remarks
None
16.42. Memory - RAM (32-bit)
Description
RAM (32-bit)
Inputs
Data (32-bit integer): Integer data input
Address store (16-bit integer): Address of the destination memory
CLK store (Logic): Clock input signal for storing data
Address load (16-bit integer): Address of the destination memory
CLK load (Logic): Clock input signal for retrieving data
Outputs
Data (32-bit integer): Stored integer data (on falling edge) in bi-directional mode
Properties
Memory size (Integer, 1 to 255): Number of memory cells
Retain on reset (Logic): If True, the value is saved to battery-backed RAM. Also
disables default value setting.
Initial value (Integer): The initial value of the retained block after it gets uploaded to
the device.
Initial RAM value (Integer): The initial value of the retained block after it gets
uploaded to the device.
Remarks
None
16.43. Memory - Sample/hold
Description
Sample/hold simulates a sample and hold element. When the sample input is
enabled, the block operates in transparent mode. When sample input is disabled, the
output retains the last value.
Inputs
Data in (32-bit integer): Integer data input
Sample (Logic): Sample input signal
Outputs
Value (32-bit integer): Stored integer data
Properties
Default value (Integer): Default reset value
Retain on reset (Logic): If True, the value is saved to battery-backed RAM. Also
disables default value setting.
Initial value (Integer): The initial value of the retained block after it gets uploaded to
the device.
Remarks
None