16.55. Extended - Look-up table (byte)
Description
Look-up table (byte) is used to select data from the table. Double-click on block to
edit configuration.
Inputs
Position (32-bit integer): Look-up table entry index
Outputs
Out (8-bit integer): Entry value
Properties
None
Remarks
Use look-up table editor to set values of the entries. Use check boxes on the left to
set number of entries in the table.
16.56. Extended - Schedule
Description
Schedule is used to setup activation schedule by configuring multiple intervals. To
setup the intervals, double click on the block in the scheme.
Inputs
None
Outputs
Out (8-bit integer): Activation signal
Out 1 - 10 (8-bit integer): Interval-specific optional ouputs.
Rule 1 - 10 (32-bit integer): interval-specific optional rule access, that can be used to
access and modify rule data using shared slots.
Properties
Separate outputs (Logic): When enabled, each interval rule drives its own output,
Out is still the OR-ed value of all.
Expose rules values (Logic): When enabled, each interval rule is connected to the
output, allowing remote changes to the intervals.
Rules (Integer, 1 to 10): Number of scheduler rules
Retain on reset (Logic): If True, the value is saved to battery-backed RAM. Also
disables default value setting.
Remarks
Use schedule editor to configure the time-based output activation rules. Up to 10
rules can be defined for a single Schedule block a slider-based interface. Double-click