User Manual
PoKeys user manual
33
www.poscope.com
Pulse engine status/control dialog parts
1. Main Pulse engine settings:
a. Enable pulse engine: main switch to enable or disable Pulse engine functionality
b. Lock: when Lock is enabled, the main Pulse engine settings and Pulse generator
settings are disabled
c. Enable safety charge pump output: configure the pin for the charge pump output
d. Invert emergency input polarity: PoKeys expects NC (normally closed switch to be
used as emergency switch) and HIGH signal state on emergency input indicates an
emergency. If NO switch is used, the polarity of the signal must be inverted by
selecting this option
e. Enable backlash compensation: check this option to enable the backlash
compensation in PoKeys device.
2. Pulse generator options: PoKeys57CNC contains an external pulse generator on-board, thus
external pulse generator option with ‘Extended IO’ must be selected. Up to 8 axes can be
enabled
3. Axis configuration - see next page
4. Pulse engine state display and control: this panel displays current PoKeys Pulse engine state
and allows the user to change between the states
a. STOP: stopped mode - the Pulse engine is deactivated momentarily and produces no
pulses. Transition to STOP mode is instantaneous - if there is any motion being
executed, the pulse generation will cease immediately after switching to STOP mode.
b. ERR: error mode - if PoKeys detects any event that results in error (emergency stop,
limit stop, etc.), this mode will automatically be activated. As STOP mode, the
transition is instantaneous
c. Homing: in this mode, PoKeys is executing the homing procedure. The selected axes
are referenced in regards to the position of Home/Ref switch. PoKeys executes
homing procedure in two steps - in first step, course position of the switch is located
using faster motion in the negative direction of the axes (unless Homing direction is
inverted in the settings). When the switch is located, the fine position of the
reference position is located using slower motion in the positive direction of the axis
(again, if not inverted in the settings) until the Home/Ref switch is released.
d. Running: normal operating mode
e. Jogging: jogging mode - in this mode, PoKeys Pulse engine can use the values from
the encoders to directly jog the configured axes
f. Emergency: this field indicates whether device entered Emergency state
g. Limit override: switch that allows the user to activate the limit override
5. Enable axis power and enable charge pump: these options select, when the axis enable and
chargepump output signals are activated (besides normal operating modes)
6. Save configuration button: after the settings are changes, this button must be clicked to
send the settings to device and save them to the on-board non-volatile memory. Since this
operation may produce interruptions in the motion, it is suggested to stop any motion
before commencing configuration save.
7. Pulse engine testing panel:
8. Additional configuration options - here, additional configuration dialogs can be opened
9. Auxilary outputs: these can be used to test the on-board auxilary outputs