Security
Due to exposed nature of a network device, an authentication mechanism was implemented in
network PoKeys that allows three levels of access rights:
- Full access (default): the device is fully accessible from the network
- Read-only access: unauthorized users are allowed only to fetch a limited set of data from the
device, while an authenticated users can acccess all functions of the device
- Full lock: unauthorised users can not neither read or write to the device. A user password is
required to unlock access.
The security is set up in PoKeys configuration software – on the Device menu, click Set device
security... The password can contain any character and can be up to 32 characters long.
Figure 40: Device security settings window