Data Sheet

TB67S279FTG
2017-09-15
9
Step resolution and set current (Electric angle: 0 to 180°)
Electrical
angle
STEP IOUTA(%) IOUTB(%) 1/32 step 1/16 step 1/8 step 1/4 step 1/2(b) step 1/2(a) step 1/1 step
1 +100 0
2 +100 +5
3 +100 +10
4 +99 +15
5 +98 +20
6 +97 +25
7 +96 +29
8 +94 +34
9 +92 +38
(Note2)
10 +90 +43
11 +88 +47
12 +86 +52
13 +83 +56
14 +80 +60
15 +77 +63
16 +74 +67
45° 17 +71 +71
(Note1) (Note1)
18 +67 +74
19 +63 +77
20 +60 +80
21 +56 +83
22 +52 +86
23 +47 +88
24 +43 +90
25 +38 +92
(Note2)
26 +34 +94
27 +29 +96
28 +25 +97
29 +20 +98
30 +15 +99
31 +10 +100
32 +5 +100
90° 33 0 +100
34 -5 +100
35 -10 +100
36 -15 +99
37 -20 +98
38 -25 +97
39 -29 +96
40 -34 +94
41 -38 +92
(Note2)
42 -43 +90
43 -47 +88
44 -52 +86
45 -56 +83
46 -60 +80
47 -63 +77
48 -67 +74
135° 49 -71 +71
(Note1) (Note1)
50 -74 +67
51 -77 +63
52 -80 +60
53 -83 +56
54 -86 +52
55 -88 +47
56 -90 +43
57 -92 +38
(Note2)
58 -94 +34
59 -96 +29
60 -97 +25
61 -98 +20
62 -99 +15
63 -100 +10
64 -100 +5
180° 65 -100 0
Note1: 1/1 step and 1/2 (a) step: Set current of 71 % corresponds to 100 %.
Note2: 1/4 step: Set current of 92 % corresponds to 100 %.