DocID031478 Rev 1 25/28
UM2356 Driver errors and warnings
28
-31
VL53L1_WARNING_OFFSET_CAL_MISSING_
SAMPLES
Thrown if there is less than the requested number of
valid samples. Ensure offset calibration setup is in line
with ST recommendations.
-32
VL53L1_WARNING_OFFSET_CAL_SIGMA_
TOO_HIGH
Thrown if the offset calibration range sigma estimate
is too high. Ensure offset calibration setup is in line
with ST recommendations.
-33
VL53L1_WARNING_OFFSET_CAL_RATE_
TOO_HIGH
Thrown when signal rate is greater than a limit and
sensor is saturating. Ensure offset calibration setup is
in line with ST recommendations.
-34
VL53L1_WARNING_OFFSET_CAL_SPAD_
COUNT_TOO_LOW
Thrown when not enough SPADS can be used.
Ensure offset calibration setup is in line with ST
recommendations.
-41 VL53L1_ERROR_NOT_IMPLEMENTED Function called is not implemented
Table 7. Bare driver errors and warnings descriptions (continued)
Error
value
API error string Occurrence