Users Manual
SME VOIP SYSTEM GUIDE 1.1 58 | P a g e
Proprietary and Confidential
Using multicast this base IP is selected automatically.
The data sync feature uses the port range: 49200 – 49999
NOTE: When using Peer to Peer mode the IP of the base used for data
sync. source MUST be defined.
NOTE: Using Peer to Peer mode with version below V306 limits the
system’s automatic recovery feature – as there is no automatic recovery of
the data sync. source in Peer to Peer mode.
MULTI CELL DEBUG None Enable this feature, if you want the system to catalogue low level multi-cell
debug information or traces.
Options:
Data Sync: Writes header information for all packets received and sent to
be used to debug any special issues. Generates LOTS of SysLog signaling
and is only recommended to enable shortly when debugging.
Auto Tree: Writes states and data related to the Auto Tree Configuration
feature.
Both: Both Data Sync and Auto Tree are enabled.
NOTE: Must only be used for debug purpose and not enabled on a normal
running system
DECT System Settings
Description of DECT Settings for Specific Base units is as follows:
Screenshot
PARAMETER DEFAULT
VALUES
DESCRIPTION
DECT SYSTEM
RFPI
May vary This is a radio network identity accessed by all Base units in a specific multi-
cell system. It is composed of 5 octets and has 5 different variables combined.
RFPI Format:
XX XX XX XX XX
(where XX are HEX values)
AUTO
CONFIGURE
DECT SYNC
SOURCE TREE
Enabled Enable this to allow the system to automatically synchronize the multi-cell
chain/tree.
NOTE: Must be enabled in order to allow a new primary to recover in case the
original primary goes into faulty mode.
ALLOW MULTI
PRIMARY
Disabled This feature is used for multi-location setups. Allows two or more primary in
the same system.
The two cells will be unsynchronized, and handover will not be possible.
“Auto Configure DECT sync source tree” must be enabled for this feature to
also be enabled
AUTO CREATE
MULTI
PRIMARY:
Disabled When enabled, the system will generate cells in case a base goes into faulty
mode. Two cells will only be generated in case no radio connection between
the two cells is present. In order to recover the full system after establishing
of the faulty base, the system must be rebooted.
“Allow multi primary” must also be enabled for this feature to work.