User's Manual
Polycom, Inc. L-1
Appendix L
Homologation for Brazil
H.323 & SIP Protocol Flag Options 
Using a set of system flags, the user has the ability to select either Polycom proprietary or 
H.323/SIP standard protocol settings.
H.323 & SIP Flag Settings
Three flags are enabled on the Collaboration Server, allowing the user to define and select 
either standard or proprietary H.323 and SIP protocol settings. 
Flag name: SIP_TIMERS_SET_INDEX
Description: SIP Timer type timeout settings according to standard or proprietary protocol.
Flag section: CS_MODULE_PARAMETERS 
Possible Values: either 0 or 1. 
0 - Polycom standard (flag default setting)
1 - SIP Standard recommendation. For homologation and certification testing, this flag must 
be set to 1.
For use as a reference, Table 1 lists the SIP timer types for each flag setting and their 
corresponding timeout values in milliseconds.
Table 1  SIP Timer Types & their Values
SIP TIMER Types
Value (in milliseconds)
POLYCOM (flag default) Standard Recommended
T1   50000 500
T2   20000 4000
TimerB  35000 32000
TimerC  35000 60000
TimerD  32000 32000
TimerF  35000 32000
TimerH  35000 32000
TimerI  5000 5000
TimerJ  32000 32000