User's Manual

Polycom, Inc. B-1
Appendix B
Active Alarms
Table B-1 Active Alarms
Alarm Code Alarm Description
A matching activation key is required. To
cancel the upgrade process, reset the
Collaboration Server
The system upgrade requires that a valid activation key be entered. If none is
available, resetting the Collaboration Server will cancel the upgrade and return
the Collaboration Server to the previous version.
A new activation key was loaded. Reset
the system.
A new activation key was loaded:
Reset the MCU.
A new version was installed. Reset the
system.
A new version was installed:
Reset the MCU.
Alarm generated by a Central Signaling
component
A system alert was generated by a component of the Central Signaling.
Alarm generated by an internal
component
A system alert was generated by an internal system component.
Allocation mode was modified
Automatic reset is unavailable in Safe
Mode
The system switches to safe mode if many resets occur during startup. To
prevent additional resets, and allow the system to complete the startup
process the automatic system resets are blocked.
Backup of audit files is required If the ENABLE_CYCLIC_FILE_SYSTEM_ALARMS is set to YES (default
setting when ULTRA_SECURE_MODE System Flag is set to YES) and a
Cyclic File reaches a file retention time or file storage capacity limit, the user is
alerted that audit files need to be backed up.
Backup of CDR files is required If the ENABLE_CYCLIC_FILE_SYSTEM_ALARMS is set to YES (default
setting when ULTRA_SECURE_MODE System Flag is set to YES) and a
Cyclic File reaches a file retention time or file storage capacity limit, the user is
alerted that CDR files need to be backed up.
Backup of log files is required If the ENABLE_CYCLIC_FILE_SYSTEM_ALARMS is set to YES (default
setting when ULTRA_SECURE_MODE System Flag is set to YES) and a
Cyclic File reaches a file retention time or file storage capacity limit, the user is
alerted that log files need to be backed up.
Bios version is not compatible with Ultra
Secure Mode.
The current BIOS version is not compatible with Ultra Secure Mode
(ULTRA_SECURE_MODE=YES).
Card configuration event
Card failed to switch to Enhanced Secure
Mode
Card failure occurred when the system was set to Ultra Secure Mode
(ULTRA_SECURE_MODE=YES).