7.8 Errors list
Code
Description
Comments
E001
Rack state is 0.
To activate the rack, use set
rack_state 1
This error is returned if the
user sends a setpoint or state
whereas rack state is 0.
E002
Rack state is already 1.
This error is returned if the
user sends the command set
rack_state 1 whereas rack
state is already 1.
E003
Impossible to initialize
measurement cards.
Check USB connection
between cards and
microcontroller inside the rack.
Switch off and on the rack.
E004
Impossible to initialize control
cards.
Check USB connection
between cards and
microcontroller inside the rack.
Switch off and on the rack.
E005
Impossible to initialize relay
cards.
Check USB connection
between cards and
microcontroller inside the rack.
Switch off and on the rack.
E006
Impossible to disconnect
measurement/control/relay
cards.
Switch off and on the rack.
E007
Setpoints or state not
recognized.
And/or
measurement/control/relay
cards not working.
If the command used is set
xxx_state <value>, make sure
<value> is an integer being
either 0 or 1.
If the command used is set xxx
<value>, make sure <value> is
a float.
Check USB connection
between cards and
microcontroller inside the rack.
Switch off and on the rack.
E008
Control/relay cards not
working.
Check USB connection
between cards and
microcontroller inside the rack.
Switch off and on the rack.
E009
Measurement cards not
working.
Check USB connection
between cards and