Use and Care Manual

9
2009 PORT-A-COOL® Unit Electric Models
32
2009 PORT-A-COOL® Unit Electric Models
IV. MAINTENANCE & STORAGE
Very little maintenance is actually required on the PORT-A-COOL® unit. The primary topic that accounts
for most of the maintenance is cleanliness. Keeping the PORT-A-COOL® unit clean will do more than any
other single item to keep your PORT-A-COOL® unit in peak operating condition. The rugged, corrosion-resis-
tant construction of the PORT-A-COOL® unit and industrial grade components make for the low maintenance
characteristics. In exceedingly dusty or dirty environments, optional filters are available from your distributor
(PAC-FRAME-16, PAC-FRAME-24, PAC-FRAME-36, PAC-FRAME-48).
A. Daily Maintenance
Daily maintenance is really more an operational consideration than actual maintenance. On a daily basis,
the pump should be turned off approximately 15 minutes before the fan is turned off. This will allow the
cooling pads to dry out and help extend their life, helping to control the growth of mildew, mold, bacteria
and other odor causing elements.
B. Weekly Maintenance
At the end of the week or at a scheduled time, the unit should be shut down and the sump tank should
be drained. Closing the Spray Bar Adjustment Valve and opening the Drain Valve accomplish this. If it is
desired, a hose may be attached to the Drain Valve to direct the drained water to a remote disposal area.
Once the Drain Valve is open, starting the pump will drain the unit. When the pump has removed most of
the water a small amount will be left in some areas. In the 16” models, removal of the drain plug will accom-
plish the same results without the use of the pump.
In the 16” SFC models, disconnect the inlet hose going into the side of the unit and use the pump to drain
the unit.
Once the sump is drained and the power disconnected, the pads may be removed to allow inspection
of the sump tank. Assuming that the PORT-A-COOL® unit is in a dusty environment, dust will collect in the
sump tank over time. This dirt and any remaining water may be vacuumed out using a wet/dry shop vacuum
and wiped clean with a cloth. Also, inspect and clean the Inlet Strainer located on the bottom of the pump.
Replace pads in correct airflow direction, referring to label on the pads.
C. Storage
Storage of the PORT-A-COOL® unit is very simple.
1) Drain all water from the sump tank and clean as above, ensuring that the pads and
sump are completely dry.
2) Roll up the electrical power cord and secure it to ensure that it will not be rolled over,
tripped over or caught in equipment.
3) Cover the PORT-A-COOL® unit completely to prevent dust build-up and store in a dry area.
This also helps prevent damage to the pads. Optional dust covers are available from your distributor.
(P/N #: PAC-CVR-01, PAC-CVR-02, PAC-CVR-03).
CAUTION: DISCONNECT POWER BEFORE REMOVING
COOLING PADS FROM THE PORT-A-COOL® unit!!
NOTICE: POWER CORD MAY BE REPLACED ONLY BY THE
MANUFACTURER OR QUALIFIED AGENT!!