Use and Care Manual
PORT-A-COOL JETSTREAM™ OWNERS MANUAL
Make sure the two locking casters have been locked to prevent the
cooler from moving before turning on the fan. Turn on the water sup-
ply to the cooler. The hose connection to the oat valve provides an
automatic method of relling the water supply as water is evaporated.
For best results, turn the pump on a few minutes before turning on the
blower fan. This allows the cooling pads to pre-wet for best efciency.
Whenever possible operate the blower fan at low speed for maximum
cooling. When cooling is not required you can operate the unit as a fan
only by turning on the blower fan and leaving the pump turned off.
WARNING: To Reduce The Risk Of Fire Or Electric Shock, Do
Not Use This Fan With Any Solid-State Speed Control Device.
At the end of the week or at a scheduled time, the unit should be shut
down and the sump tank should be drained. To drain, remove small
drain plug in the rear of the unit. Replace securely when nished.
Once the sump is drained and the power disconnected, the pads may be
removed to allow inspection of the sump tank. Assuming that the Port-
A-Cool Jetstream™ 1600 unit is in a dusty environment, dust will collect
in the sump tank over time. This debris and any remaining water may be
vacuumed out using a wet/dry shop vacuum and wiped clean with a cloth.
Also, inspect and clean the Inlet Strainer located on the pump. Replace
pads in correct airow direction, referring to label on the pads.
Storage. Storage of the Port-A-Cool Jetstream™ 1600 unit is very simple.
1) Drain all water from the sump tank and clean as above, ensuring that the
pads and sump are completely dry.
CAUTION: DISCONNECT POWER BEFORE REMOVING
COOLING PADS FROM THE PORT-A-COOL® unit!!
PAGE
3
OPERATING INSTRUCTIONS
Jetstream UNIT MAINTENANCE & STORAGE