Use and Care Manual

PORT-A-COOL JETSTREAM™ OWNERS MANUAL
Make sure the two locking casters have been locked to prevent the
cooler from moving before turning on the fan. Turn on the water sup-
ply to the cooler. The hose connection to the oat valve provides an
automatic method of relling the water supply as water is evaporated.
For best results, turn the pump on a few minutes before turning on the
blower fan. This allows the cooling pads to pre-wet for best efciency.
Whenever possible operate the blower fan at low speed for maximum
cooling. When cooling is not required you can operate the unit as a fan
only by turning on the blower fan and leaving the pump turned off.
WARNING: To Reduce The Risk Of Fire Or Electric Shock, Do
Not Use This Fan With Any Solid-State Speed Control Device.
At the end of the week or at a scheduled time, the unit should be shut
down and the sump tank should be drained. To drain, remove small
drain plug in the rear of the unit. Replace securely when nished.
Once the sump is drained and the power disconnected, the pads may be
removed to allow inspection of the sump tank. Assuming that the Port-
A-Cool Jetstream™ 1600 unit is in a dusty environment, dust will collect
in the sump tank over time. This debris and any remaining water may be
vacuumed out using a wet/dry shop vacuum and wiped clean with a cloth.
Also, inspect and clean the Inlet Strainer located on the pump. Replace
pads in correct airow direction, referring to label on the pads.
Storage. Storage of the Port-A-Cool Jetstream™ 1600 unit is very simple.
1) Drain all water from the sump tank and clean as above, ensuring that the
pads and sump are completely dry.
CAUTION: DISCONNECT POWER BEFORE REMOVING
COOLING PADS FROM THE PORT-A-COOL® unit!!
PAGE
3
OPERATING INSTRUCTIONS
Jetstream UNIT MAINTENANCE & STORAGE