PORTACOOL CYCLONE OWNER’S MANUAL ™
TABLE OF CONTENTS READ AND SAVE THESE INSTRUCTIONS FOR ELECTRIC MODELS PAC2KCYC01, PAC2KCYC01A, PACCYC02, PACCYC02A, PACCYC03, PACCYC03A PACCYC04, PACCYC04A, PACCYC05 ,PACCYC06 INCLUDES EXPORT MODELS PACCYC01-22050, PACCYC01-22060, PACCYC01-22050A, PACCYC01-22060A, PACCYC02-22050, PACCYC02-22060, PACCYC02-22050A, PACCYC02-22060A CONTENTS: QUICK SETUP GUIDE.......................................................................... page 2 TROUBLESHOOTING.......................................................
QUICK SET UP 1 2 Remove box and palette 5 Position product on level surface 3 Fill sump or attach water hose For setup, pads should appear wet before starting the fan. Check the water gauge to monitor water level in tank.The water flow valve on each unit is set at max flow. However, ensure the knob is turned completely to the left before use. Turn to the right to increase water flow. Less water is required for cooling in more humid environments.
CYCLONE 3000 OVERVIEW PAC2KCYC01, PAC2KCYC01A Control Panel Adjustable Louvers Adjustable Louvers Water Adjustment Valve Hose Connection 3 Locking Casters Drain Plug Electrical Plug
CYCLONE 3200 OVERVIEW PACCYC04, PACCYC04A Control Panel Adjustable Louvers Adjustable Louvers Hose Connection Water Adjustment Valve Locking Casters Drain Plug Electrical Plug 4
CYCLONE 2000 OVERVIEW PACCYC02, PACCYC02A Control Panel Adjustable Louvers Adjustable Louvers Electrical Plug 5 Locking Casters Water Adjustment Valve Drain Plug Hose Connection
CYCLONE 2200 OVERVIEW PACCYC03, PACCYC03A Control Panel Adjustable Louvers Adjustable Louvers Electrical Plug Locking Casters Drain Plug Water Adjustment Valve Hose Connection 6
CYCLONE 1000 OVERVIEW PACCYC06 Control Panel Adjustable Louvers Water Tank Recessed Casters 7 Drain Plug Electrical Cord
SAFETY INFORMATION UNIT OPERATION WARNINGS 1) 2) 3) 4) Not intended for use by children Not intended for use by persons with reduced physical, sensory, or mental capabilities Not intended for use by persons with lack of experience and knowledge, unless they have been given instruction and are supervised during operation Children should be supervised to ensure they do not play with the appliance SAFE OPERATION To reduce the risk of electric shock, fire, or injury: • • • • • • • • • • • Do not operate any
GENERAL OPERATION Electrical Connection PRODUCT MUST BE IN UPRIGHT POSITION WITH COOLING PADS INSTALLED! All models utilize a single power cord and control switches. Before connecting the plug to an outlet, ensure there is no standing water where the cord may lie or where the operator is standing. The use of separate multiple outlet devices is not recommended. When making electrical connections, ensure compliance to local and national codes. Use only with GFCI Protected Receptacles.
3) If placed near a wall or other obstruction, position the product a minimum of 3 feet (0.9 meters) from the wall or obstruction with pads facing the wall. This allows the unrestricted flow of warm air to the cooling pad side of the product. When using multiple products in close proximity, be sure to aim the product so the air flows complement each other to achieve maximum cooling capacity.
MAINTENANCE & STORAGE MAINTENANCE 1) Keep the product clean to ensure peak operating performance. 2) The rugged, corrosion-resistant construction ensures low maintenance will be required. However, in dusty or dirty environments, optional filters are available from your distributor or at www.portacoolparts.com. Daily Maintenance The pump should be turned off approximately 15 minutes before the fan is turned off. This will allow the cooling pads to dry out and extend their life.
TROUBLESHOOTING The Portacool evaporative cooler consists of three systems — the fan system, the electrical system, and the water system. It is important to determine with which of the systems the problem is associated. Certain problems may be associated with more than one system. A careful check of all systems should be made to fully understand the extent of the problem.
The following troubleshooting guide is intended to address the most common symptoms which may occur. If you are unable to resolve the issue, please call Technical Support. Turn off all power to the cooler before attempting to troubleshoot any of the following symptoms. SYMPTOM POSSIBLE CAUSES REMEDY Product fails to start or deliver air 1. No electrical power to product 1. Check power A. Circuit breaker tripped A. Reset breaker* B. GFCI tripped B. Reset GFCI* C.
TECHNICAL SUPPORT TECHNICAL SUPPORT Technical support and service is available directly from your distributor or call Portacool, LLC Technical Support Hot Line at 888-266-5243 for the distributor nearest you. You may also contact the Support Hot Line for consultation on troubleshooting and parts replacement. Please have serial number and model number of unit available.
RETURNS Returned Merchandise Authorization (RMA) Procedures All Portacool evaporative coolers, parts, or materials being returned to Portacool, LLC for warranty replacement or repair require an RMA (Return Merchandise Authorization) number. Warranty parts can be replaced by: 1. The distributor can purchase the part with an RMA number and will only be charged for the cost of the part, not for the shipping.
CYCLONE 1000 PARTS PACCYC06 ITEM# PART # DESCRIPTION ITEM# PART # DESCRIPTION 1 ACCDOOR-C1-714 WATER FILL DOOR FOR CYCLONE1000 22 PUMP-CYC-3 CYCLONE PUMP -OK4000 2 ACCFRM-C1-715 FILL DOOR FRAME FOR CYCLONE1000 23 S-002 #8 x 3/4" TEK SCREW (2EA) 3 BLOWER-WHL-2CW CYCLONE 2000 BLOWER WHEEL - CW 24 S-003 5/16 - 18 x1/2" TRUSS HEAD SCREW (2EA) 4 BLWEHSG-C1-7162 BLOWER HOUSING FOR CYCLONE1000 25 S-007 5/16 - 18 x 3/4 TRUSS HEAD SCREW (16EA) 5 BLWRCVR-C1-7163 BLOWER HOUSING COVER F
CYCLONE 3000 PARTS PAC2KCYC01 PAC2KCYC01A 4 14 16 24 5 25 11 28 10 29 33 31 30 22 20 12 32 10 19 33 13 21 34 18 20 23 15 27 9 2 3 26 1 8 17 7 17 PART # REVISED 02/04/2015 6 DESCRIPTION ITEM# PART # DESCRIPTION 1 BASE-CYCLONE CADDY FRAME 18 PAC-PLB-01 INLET HOSE ADAPTER 2 BLOWER-01 BLOWER HOUSING 19 PAD6022.5/26 KUUL PAD SET FOR CYCLONE 3 BLOWER-WHL-01 BLOWER WHEEL 20 POLY-FTG-06 90 DEG.
CYCLONE 2000 PARTS PACCYC02 PACCYC02A 24 REVISED 02/04/2015 4 26 14 9 26 22 15 28 25 10 19 18 5 31 11 30 20 9 29 8 16 21 14 27 13 12 23 PART # DESCRIPTION PART # DESCRIPTION 1 BLOWER-02 BLOWER HOUSING - CYCLONE2000 17 MOTOR-016-01 CYCLONE2000 - 2SPD MOTOR 2 BLOWER-WHL-2CW CYCLONE2000 BLOWER WHEEL (PART 1) 18 PAC-PLB-14 INLET HOSE ADAPTER for CYCLONE2000 3 BLOWER-WHL-3CCW CYCLONE2000 BLOWER WHEEL (PART 2) 19 PAD6019/22 KUUL PAD SET FOR CYCLONE2000 4 BONNET-06 22.
CYCLONE 2200 PARTS PACCYC03 PACCYC03A 27 27 15 26 9 31 5 30 9 17 21 29 9 14 8 7 12 22 13 24 16 19 19 11 10 20 PART # 4 33 28 NEW 01/31/15 25 14 25 1 2 3 6 18 19 DESCRIPTION PART # DESCRIPTION 1 BLOWER-02 BLOWER HOUSING - CYCLONE2000 17 PAC-PLB-14 INLET HOSE ADAPTER for CYCLONE2000 2 BLOWER-WHL-2CW CYCLONE2000 BLOWER WHEEL (PART 1) 18 PAD6019/G KUUL PAD FOR CYCLONE2200 3 BLOWER-WHL-3CCW CYCLONE2000 BLOWER WHEEL (PART 2) 19 PAD6019/5G KUUL PAD SET FOR C
CYCLONE 3200 PARTS PACCYC04 14 PART # 4 PACCYC04A 26 29 30 16 33 10 12 25 35 19 33 31 5 10 11 32 23 22 PART # DESCRIPTION BASE-CYCLONE CADDY FRAME 19 PAD6022.5/G 6"x12"x22" KUUL PAD FOR CYCLONE 2 BLOWER-01 BLOWER HOUSING 20 PAD6022.7G 6"x7"x22" KUUL PAD FOR CYCLONE 3 BLOWER-WHL-01 BLOWER WHEEL 21 POLY-FTG-06 90 DEG.
WIRING DIAGRAM 21
FREQUENTLY ASKED QUESTIONS Q. WHAT ASSEMBLY IS REQUIRED? A. None. Portacool Cyclone units are ready to use right out of the box. Q. HOW DO I PREPARE MY PORTACOOL PRODUCT FOR STORAGE? A. Drain the product, dry out the pads, cover the unit, and store the unit in a dry place. Q. I JUST RAN THE COOLER FOR THE FIRST TIME AND THERE’S AN UNPLEASANT ODOR! A. The pads, located in the back of your Portacool unit, have never been wet before.
CUSTOMER SERVICE CONTACT 1-936-598-5651 • 1-800-695-2942 ORDERS@PORTACOOL.COM TECHNICAL/PARTS CONTACT 1-936-598-5651 • 1-866-COOLAID SUPPORT@PORTACOOL.COM VISIT PORTACOOL.COM OR CALL1-936-598-5651 FOR MORE INFORMATION Portacool, LLC • Manufacturer of Portacool™ portable evaporative coolers and KÜÜL® Pads evaporative media 709 Southview Circle • Center, Texas 75935 • 936-598-5651 • www.portacool.com • www.kuulpads.