PORTACOOL JETSTREAM OWNER’S MANUAL PACJS220, PACJS230, PACJS240, PACJS250, PACJS260, PACJS270
QUICK SETUP 1 2 3 Remove box and pallet Position cooler on level surface 4 Fill tank or attach water hose* Plug into appropriate outlet *Maximum water pressure 50 psi/345 kPa 5 For setup, Kuul® evaporative media should appear wet before starting the fan. Check the water gauge to monitor water level in tank. The water adjustment valve on each portable evaporative cooler is set at max flow. However, ensure the knob is turned completely to the right before use. Turn to the left to increase water flow.
SAFETY OPERATION WARNINGS 1) Not for use by children 2) Not for use by persons with reduced physical, sensory or mental capabilities 3) Not for use by persons who have not reviewed the owner’s manual and familiarized themselves with the operation of the product. SAFE OPERATION To reduce the risk of electric shock, fire or injury: • Do not operate any evaporative cooler with a damaged cord or plug. • Do not run power cord under carpeting or cover with throwrugs, runners or similar coverings.
OVERVIEW Serial plate PACJS220 Water adjustment valve Control panel Oscillating louvers Liquid Level Indicator Hose connection Cord wrap Manual water fill Heavy duty casters Two inch drain on bottom Power cord with GFCI Kuul® Comfort MicroTech evaporative media
OVERVIEW PACJS230 Serial plate Water adjustment valve Liquid Level Indicator Oscillating louvers Control panel Hose connection Cord wrap Manual water fill Power cord with GFCI Heavy duty casters Two inch drain on bottom Kuul® Comfort MicroTech evaporative media
OVERVIEW Serial plate PACJS240 Control panel Water adjustment valve Liquid Level Indicator Cord wrap Hose connection Manual water fill Heavy duty casters Two inch drain on bottom Power cord with GFCI Kuul® Comfort evaporative media
OVERVIEW PACJS250 Serial plate Water adjustment valve Liquid Level Indicator Control panel Manual water fill Cord wrap Hose connection Power cord with GFCI Kuul® Comfort evaporative media Heavy duty casters Two inch drain on bottom
OVERVIEW PACJS260 Serial plate Water adjustment valve Control panel Liquid Level Indicator Hose connection Manual water fill Cord wrap Power cord with GFCI Kuul® Comfort evaporative media Heavy duty casters Two inch drain on bottom
OVERVIEW PACJS270* Serial plate Water adjustment valve Control panel Liquid Level Indicator Hose connection Manual water fill Cord wrap Power cord with ELCI Kuul® Comfort evaporative media Heavy duty casters *requires a 5-20R power outlet Two inch drain on bottom
GFCI/ELCI The Portacool Jetstream™ series utilizes a GFCI (Grounded Fault Circuit Interrupter) or ELCI (Equipment Leakage Circuit Interrupter) to help protect users against ground electrical faults, which prevent some fire and electrical shock hazards. These devices are intended to trip at very low leakage currents.
LLI LIQUID LEVEL INDICATOR / PUMP SHUTOFF A liquid level indicator with integral shutoff gives a visual indication of the water level in the evaporative cooler and will shut off the pump once the water reaches a certain threshold. When this occurs, a red light on the control panel will illuminate to draw attention to the low water level condition and alert the user that the pump has shut off.
START UP PLACEMENT 1) Make sure there is a clear, unobstructed path in front of the evaporative cooler to provide maximum airflow. 2) If the evaporative cooler is positioned on a raised platform, ensure the platform is stable, well constructed, and will not allow the evaporative cooler to tip over and that it allows for the full weight of the evaporative cooler including a tank full of water. The cooler must be level and in the upright position.
MAINTENANCE While the rugged, corrosion-resistant construction ensures low maintenance will be required, keeping your evaporative cooler clean will ensure it stays in peak operating condition. DAILY MAINTENANCE The pump should be turned off approximately 15 minutes before the fan is turned off, which allows the Kuul® evaporative media to dry.
TROUBLESHOOT Turn off all power to the evaporative cooler before attempting to troubleshoot any of the following symptoms. For problems not listed, please contact Customer Service. REMEDY SYMPTOM POSSIBLE CAUSES Evaporative cooler fails to start or deliver air 1. No electricity to the evaporative cooler A. Circuit breaker tripped B. GFCI tripped C. Power unplugged or damaged 2. Motor overheated and/or frozen 2. Replace motor 1.
TROUBLESHOOT SYMPTOM POSSIBLE CAUSES REMEDY Musty or unpleasant odor 1. Stale or stagnant water in tank 2. Kuul evaporative media is mildewed or clogged 1. Drain, flush and clean tank Water droplets in the air stream 2. Replace Kuul evaporative media 1. Too much water delivered to Kuul evaporative media 1. Make sure Kuul evaporative media is properly positioned in the frames and evaporative cooler is level 2. Leaking hose 2.
WARRANTY TECHNICAL SUPPORT Technical support and service is available directly from your distributor or call Portacool, LLC Customer Service at (800) 695-2942 for the distributor nearest you. You may also contact Customer Service for consultation on troubleshooting and parts replacement. Please have serial number and model number of evaporative cooler available.
PORTACOOL PROTECT Portacool, LLC is proud to provide world-class service and support. Portacool Protect™ brings together our commitment to service and support in the form of best-in-class warranties, service programs, technical support and live customer service to provide our customers with an ownership experience that is second to none.
FAQ Q. What assembly is required? A. None. Portacool Jetstream evaporative coolers are ready to use right out of the box. Q. How do I prepare my evaporative cooler for storage? A. Drain the evaporative cooler, dry out the evaporative media, cover the evaporative cooler and store in a dry place. Q. How often should my Kuul ComfortTM evaporative media be replaced? A. Depending on the quality of maintenance and frequency of use, Kuul Comfort evaporative media typically last up to five years.
FAQ Q. Where are the model and serial numbers found? A. The model number can be found on a metal plate on the outside of the evaporative cooler. Model numbers begin with the letters “PAC.” Serial numbers are all digits. Q. What if my questions are not answered here? A. Check out our videos on www.portacool.com or our YouTube channel. Our U.S.-based Customer Service staff is available 8 a.m. to 5 p.m. Central Time, Monday though Friday at (800) 695-2942 or you can e-mail them at support@portacool.com.
PARTS PRODUCTS SOLD IN THE UNITED STATES, CANADA AND MEXICO MOTOR PUMP MEDIA CONTROLS COVER HARD WATER TREATMENT 220 230 240 250 260 270 PARMTRJ2200A PARMTRJ2300A PARMTRJ2400A PARMTRJ2500A PARMTRJ2600A PARMTRJ2700A PARPMP00020A PARPMP00020A PARPMPJ2400A PARPMPJ2500A PARPMPJ2600A PARPMPJ2700A PARKULJ22000 PARKULJ23000 PARKULJ24000 PARKULJ25000 PARKULJ26000 PARKULJ27000 PARCTLJ22000 PARCTLJ23000 PARCTLJ24000 PARCTLJ25000 PARCTLJ26000 PARCTLJ27000 PARCVRJ22000 PARCVRJ23000 PARC
NOTES
NOTES
NOTES
CUSTOMER SERVICE CONTACT 1-936-598-5651 • 1-800-695-2942 SUPPORT@PORTACOOL.COM TECHNICAL/PARTS CONTACT 1-936-598-5651 • 1-800-695-2942 SUPPORT@PORTACOOL.COM VISIT PORTACOOL.COM The manual is available in other languages. To download a digital copy, please visit www.portacool.com. El manual está disponible en otros idiomas. Para descargar una copia digital, por favor visite www.portacool.com. Le manuel est disponible en d’autres langues.