User Manual

OmniFlex Plus PortaMax 458S PortaMax 600S PortaMax 458A Porta-Panel II Series 300
Wall thickness 3" 4 5/8" 6" 4 5/8" 1 3/4" 3"
Maximum height* 18 feet 24 feet 40 feet 24 feet 12 feet 18 feet
Loadbearing Yes Yes Yes Yes No Yes
Stud design 2 piece 3 piece 3 piece 2 piece 2 piece 2 piece
(all nonprogressive)
Steel Steel Steel Aluminum Aluminum Aluminum
2 cover plates 2 cover plates 2 cover plates 2 cover plates 1 cover plate 1 cover plate
Framing Finish Champagne, Gray Champagne, Gray Champagne, Gray Anodized Anodized Anodized
Systems Selector Guide
The purpose of this guide is to help
you select the most suitable PortaFab
building system, based on an
organized analysis of construction
features required for your application.
Definition of Terms
Nonprogressive Wall Systems
Completely demountable and re-usable,
nonprogressive wall systems permit the
removal of any panel, including those with
door or windows, without disturbing
adjacent panels or ceiling.
Expansion, reconfiguration, moving to a new
location are all simple and inexpensive with
a nonprogressive system.
Non-Loadbearing Wall System
A wall system designed to support the
weight of the ceiling, lights and dust cover.
Any additional loading may require
structural support. Please consult factory.
Loadbearing Roof Wall System
A wall system designed to support any type
of roof loading beyond the weight of the
lights and ceiling itself. Design criteria
include man loads, 2-story, roof-mounted
HVAC and duct work, and storage loads.
Please consult factory for specific needs.
Extended Height Wall System
Increased wall heights are available based
on your needs, such as specified ceiling
height, floor to roof applications, machinery
clearance required, or if a ceiling plenum is
required to conceal and house equipment.
Standard Panel Construction
Interior and exterior facings of 1/8”
vinyl-covered hardboard with a core of
kraft honeycomb.
Fire & Sound Control Panel
Construction
Provides a Class A noncombustible
rating, increased sound deadening and
thermal insulation.
18
Optional Panel Constructions
See Page 19.
Sound Control
Provides a greater sound transmission
coefficient (STC) rating. This is ideal for
areas where plant noise can be especially
disruptive.
Noncombustibility
A flame spread rating not greater than 50
when tested in accordance with ASTM E84.
Thermal Control
Provides an increased thermal value.
A smart choice if thermal insulation is a
consideration because of unconditioned
warehouse space, which is neither
heated or cooled.
For further technical assistance
call 1-800-325-3781 or e-mail
us at info@portafab.com.
System Comparison Guide
Panel Finishes
Champagne
Standard Finish:
White
Standard Finish:
Gray
Standard Finish:
Vinyl Hardboard
Vinyl Gypsum
Painted Surfaces
FRP
Vinyl Hardboard
Vinyl Gypsum
Painted Surfaces
Vinyl Hardboard
Vinyl Gypsum
Painted Surfaces
Custom Colors
Available
Please contact us
for color match.
or White
or White
aluminum
or White
aluminum
aluminum
*Meets L/120 criteria