Instruction manual ESPAÑOL: PÁGINA 25 FRANÇAIS: PAGE 49 MODELS CFFR350B CFFC350B To learn more about Porter-Cable visit our website at: http://www.porter-cable.com Oilfree Portable Air Compressor IMPORTANT Please make certain that the person who is to use this equipment carefully reads and understands these instructions before starting operations. The Model and Serial No. plate is located on the frame. Record these numbers in the spaces below and retain for future reference. Model No. Type Serial No.
SAFETY GUIDELINES - DEFINITIONS This manual contains information that is important for you to know and understand. This information relates to protecting YOUR SAFETY and PREVENTING EQUIPMENT PROBLEMS. To help you recognize this information, we use the symbols below. Please read the manual and pay attention to these symbols. Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury.
IMPORTANT SAFETY INSTRUCTIONS Save these instructions Improper operation or maintenance of this product could result in serious injury and property damage. Read and understand all warnings and operation instructions before using this equipment. HAZARD WARNING: Risk of explosion or fire What Could Happen How To Prevent It It is normal for electrical contacts within the motor and pressure switch to spark.
HAZARD WARNING: Risk of Bursting Air Tank: The following conditions could lead to a weakening of the tank, and result in a violent tank explosion and could cause property damage or serious injury. What Could Happen How To Prevent It Drain tank daily or after each use. If tank develops a leak, replace it immediately with a new tank or replace the entire compressor. Failure to properly drain condensed water from tank, causing rust and thinning of the steel tank.
HAZARD WARNING: Risk of Electrical Shock What Could Happen How To Prevent It Your air compressor is powered by electricity. Like any other electrically powered device, If it is not used properly it may cause electric shock. Never operate the compressor outdoors when it is raining or in wet conditions. Never operate compressor with protective covers removed or damaged. Repairs attempted by unqualified personnel can result in serious injury or death by electrocution.
HAZARD WARNING: Risk of Burns What Could Happen How To Prevent It Never touch any exposed metal parts on compressor during or immediately after operation. Compressor will remain hot for several minutes after operation. Do not reach around protective shrouds or attempt maintenance until unit has been allowed to cool. Touching exposed metal such as the compressor head or outlet tubes, can result in serious burns.
HAZARD WARNING: Risk of Serious Injury or Property Damage When Transporting Compressor (Fire, Inhalation, Damage to Vehicle Surfaces) What Could Happen How To Prevent It Oil can leak or spill and could result in fire or breathing hazard; serious injury or death can result. oil leaks will damage carpet, paint or other surfaces in vehicles or trailers. Always place COMPRESSOR on a protective mat when transporting to protect against damage to vehicle from leaks.
SPECIFICATIONS Model No. Horsepower Peak Bore Stroke Voltage-Single Phase Minimum Branch Circuit Requirement Fuse Type Air Tank Capacity (Gallon) Approximate Cut-in Pressure Approximate Cut-out Pressure SCFM @ 90 PSIG CFFR350B CFFC350B 3.0 2.375" 1.35" 120 15 amps Time Delay 4.5 105 PSIG 135 PSIG 5.3 GLOSSARY Become familiar with these terms before operating the unit. CFM: Cubic feet per minute. SCFM: Standard cubic feet per minute; a unit of measure of air delivery.
ASSEMBLY Unpacking 1. Remove unit from carton and discard all packaging. INSTALLATION HOW TO SET UP YOUR UNIT Location of the Air Compressor G G G G G Locate the air compressor in a clean, dry, and well ventilated area. Place on a solid surface to prevent rocking or tipping. The air compressor should be located at least 12" away from the wall or other obstructions that will interfere with the flow of air.
Extension Cords Using extension cords is not recommended. The use of extension cords will cause voltage to drop resulting in power loss to the motor and overheating. Instead of using an extension cord, increase the working reach of the air hose by attaching another length of hose to its end. Attach additional lengths of hose as needed.
OPERATION Know Your Air Compressor READ THIS OWNER’S MANUAL AND SAFETY RULES BEFORE OPERATING YOUR UNIT. Compare the illustrations with your unit to familiarize yourself with the location of various controls and adjustments. Save this manual for future reference. Description of Operation Become familiar with these controls before operating the unit. On/Auto/Off Switch (A): Turn this switch ON to provide automatic power to the pressure switch and OFF to remove power at the end of each use.
Cooling System (not shown): This compressor contains an advanced design cooling system. At the heart of this cooling system is an engineered fan. It is perfectly normal for this fan to blow air through the vent holes in large amounts. You know that the cooling system is working when air is being expelled. Air Compressor Pump (not shown): Compresses air into the air tank. Working air is not available until the compressor has raised the air tank pressure above that required at the air outlet.
Before Starting Break-in instructions Serious damage may result if the following break-in instructions are not closely followed. This procedure is required before the air compressor is put into service and when the check valve or a complete compressor pump has been replaced. 1. Make sure the On/Auto/Off lever is in the "OFF" position. NOTE: If quick connect is installed, pull coupler back until it clicks to prevent air from escaping through the quick connect. 2.
How to Start: 1. Turn the On/Auto/Off lever to "ON/AUTO" and allow tank pressure to build. Motor will stop when tank pressure reaches "cut-out" pressure. 2. Pull the regulator knob out and turn clockwise to increase pressure. When the desired pressure is reached push knob in to lock in place. The compressor is ready for use. NOTE: Always operate the air compressor in well-ventilated areas free of gasoline or other combustible vapors.
How to transport unit The unit has a handle (a) for carrying and a handle (b) for pulling. 1. Grasp carrying handle (a) to lift unit. a b 2. Slide handle (b) out until it locks into place. a b 3. Pull unit as shown, do not push unit. NOTE: When transporting do not lift the unit to the point where it would tip over backwards. IMPORTANT: Only use pulling handle to pull unit, use the carrying handle to lift and carry unit.
MAINTENANCE Customer Responsibilities Before each use Check Safety Valve Drain Tank Air Filter Air compressor pump intake and exhaust valves Daily or after Frequently Yearly each use ● ● ●1 ● 1- more frequent in dusty or humid conditions Unit cycles automatically when power is on. When performing maintenance, you may be exposed to voltage sources, compressed air, or moving parts. Personal injuries can occur.
To Drain Tank 1. Set the On/Auto/Off lever to "OFF". 2. Pull the regulator knob out and turn counterclockwise to set the outlet pressure to zero. 3. Remove the air tool or accessory. 4. Pull ring on safety valve allowing air to bleed from the tank until tank pressure is approximately 20 psi. Release safety valve ring. 5. Drain water from air tank by opening drain valve (counter-clockwise) on bottom of tank. Water will condense in the air tank.
SERVICE AND ADJUSTMENTS Unit cycles automatically when power is on. When doing Maintenance, you may be exposed to voltage sources, compressed air or moving parts. Personal injuries can occur. Before performing any Maintenance or repair, unplug the compressor and bleed off all air pressure. ALL MAINTENANCE AND REPAIR OPERATIONS NOT LISTED MUST BE PERFORMED BY TRAINED SERVICE TECHNICIAN. • • • Before servicing: Unplug or disconnect electrical supply to the air compressor. Bleed tank of pressure.
STORAGE Before you store the air compressor, make sure you do the following: 1. Review the "Maintenance" section on the preceding pages and perform scheduled maintenance as necessary. 2. Set the On/Auto/Off lever to "OFF". 3. Turn the regulator counterclockwise and set the outlet pressure to zero. 4. Remove the air tool or accessory. 5. Pull ring on safety valve allowing air to bleed from the tank until tank pressure is approximately 20 psi. Release safety valve ring. 6.
TROUBLESHOOTING Performing repairs may expose voltage sources, moving parts or compressed air sources, moving parts or compressed air sources. Personal injury may occur. Prior to attempting any repairs, unplug the air compressor and bleed off all air tank air pressure. PROBLEM CAUSE CORRECTION Pressure switch does not Excessive tank pressure - safety shut off motor when compressor reaches valve pops off. "cut-out" pressure.
PROBLEM CAUSE Pressure reading It is normal for "some" on the regulated pressure drop to occur. pressure gauge drops when an accessory is used. Knocking Noise. Possible defect in safety valve. Defective check valve. Compressor is not supplying enough air to operate accessories. Regulator knob has continuous air leak.
PROBLEM Regulator will not shut off air outlet. Motor will not run. CAUSE Damaged regulator. CORRECTION Replace. Motor overload protection switch has tripped. Let motor cool off and overload switch will automatically reset. Motor will start automatically when tank pressure drops below "cut-in" pressure of pressure switch. Check for proper gauge wire and cord length. Tank pressure exceeds pressure switch "cut-in" pressure. Extension cord is wrong length or gauge. Check valve stuck open.
NOTES 23- ENG A01787
LIMITED WARRANTY PORTER-CABLE CORPORATION warrants to the original purchaser that all products covered under this warranty are free from defects in material and workmanship. Products covered under this warranty include air compressors, air tools, service parts, pressure washers, and generators, which have the following warranty periods: 3 YEARS - Limited warranty on 2-stage oil-free air compressor pumps that operate at 1725 RPM. 2 YEARS - Limited warranty on oil-lubricated air compressor pumps.