FINISH NAILER MODEL FN250B _! i!_i_!_!i_i_i_!i_!_!!ii_!_ii!i_iii!_!!_+iii_i_iii_i+_i_i_i_!ii!!_i_!ii IMPORTANT TO l_h m_ _t+b+__im'tm++Cabl+ Please make certain that the person who is to use this equipment carefully reads and understands these instructions before starting operations. The Model and Serial No. plate is located on the main housing of the tool. Record these numbers in the spaces below and retain for future reference. Model No. Type Sedal No. Part No.
PORTER+CABLE Porter-Cable Corporation 4825 Highway 45 North Jackson, TN 38305 GB ENGLISH EC-DECLARATION FORMITY OF CON- We declare under our sole responsibility that this product is in conformity with the regulations 89/392/EEC; 73/23/EEC; 89/336/EEC.
GENERAL SAFETY RULES [] DANGER: When using pneumatic tools, basic safety precautions should always be followed to reduce the risk of personal injury, including the following: READ AND FOLLOW ALL INSTRUCTIONS. There are certain applications for which this tool was designed.
7. Wear ear protection to safe-guard against possible hearing loss. Fig. 5. 8. Usa clean, dry, regulated, compressed air at 70 to 120 PSI, (4.8 to 8.3 BAR). Fig. 6. g. Do not connect tool to pressure which potentially exceeds 200 PSI (13.7 BAR). 10. Only use air hose that is rated for a maximum working pressure of at least 150 PSI (10.3 BAR) or 150% of the maximum system pressure, which ever is greater. 11.
Fig. 12 Fig. 11 _ 21, Remove finger from trigger when not driving fasteners. Never carry tool with finger on trigger: tool will fire a fastener if safety is bumped while trigger is depressed. Fig. 14. 22. Do not overreach. Keep proper footing and balance at all times when using or handling the tool. 23. Fire fasteners into work surface only: never into materials too hard to penetrate. Fig. 15. 24.
TECHNICAL SPECIFICATIONS Noise level A - Weighted sound impulse power level ....... 96 dBA P - Emission sound pressure pressure level ...... 89 dBA EMPLOYER'S Typical Mean effective Acceleration ...... 3 m/s _ RESPONSIBILITIES [] DANGER: Employer must enforce compliance with the safety warnings and all other instructions contained in this manual. Keep this manual available for use by all people assigned to use this tool.
PREPARING THE TOOL 1. After reading and understanding this entire manual, connect tool to air supply (Fig. 18). [] DANGER: Never point tool at yourself or others in work area. • Always connect tool to air supply before loading fasteners (Fig. 18). • Do not load fasteners with trigger or safety depressed. • Only use approved Porter-Cable fasteners. • Operator and others in work area MUST wear safety glasses with side shields. Always wear ANSI Z87.
5. Adjust directional exhaust deflector (A) Fig. 22, so that the exhaust air blast will be directed away from the operator. The exhaust deflector provides eight detented positions for directing the exhaust blast away from the operator. Grasp the deflector and rotate it to the desired position for the current application. OPERATING INSTRUCTIONS USING THE TOOL WITH DIFFERENT TRIGGERING OPTIONS Complete all steps of PREPARING THE TOOL before using the tool.
_qWARNING: Disconnect tool from air supply before performing maintenance, clearing a jammed fastener, leaving work area, moving tool to another location, or handing the tool to another person. [] WARNING: Clean and inspect tool daily. Carefully check for proper operation of trigger and safety mechanism. Do Not use the tool unless both the trigger and the safety mechanism are functional, or if the tool is leaking air or needs any other repair.
MAINTENANCE CLEAN AND INSPECT DALLY []WARNING: Disconnect tool from air supply before cleaning and inspection.Correct all problemsbefore placingthe tool back in use. Wipe tool clean and inspect for wear or damage. Use non-flammable cleaning solutions to wipe exterior of tool only if necessary. DO NOT SOAK tool with cleaning solutions. Such solutions can damage internal parts.
ACCESSORIES A complete line of accessories is available from your Porter-Cable • Delta Supplier, Porter-Cable • Delta Factory Service Centers, and Porter-Cable Authorized Service Stations. Please visit our Web Site www.oorter-cable.com for a catalog or for the name of your nearest supplier. [] WARNING: Since accessories, other than those offered by Porter-Cable • Delta, have not been tested with this product, use of such accessories could be hazardous.
PORTER-CABLE LIMITED ONE YEAR WARRANTY Porter-Cable warrants its nailing and stapling tools for a period of one year from the date of original purchase. We will repair or replace at our option, any part or parts of the product and accessories covered under this warranty which, after examination, proves to be defective in workmanship or material during the warranty period.
PORTER-CABLE • DELTA SERVICE CENTERS (CENTROS DE SERVICIO DE PORTER-CABLE • DELTA) (CENTRE DE SERVICE PORTER-CABLE • DELTA) Parts and Repair Service for Porter-Cable (Obtenga Refaccion [Locations de Partes o Servicio o4 vous trouverez • Delta Power Tools are Available para su Herramienta les pi_ces de rechange en los Siguientes n6cessairas at These Locations Centro_ de Porter-Cable ainsi qu'un servi_ • Delta) d'entratlen) _IZONA ILUNC]a MINNESOTA CleveLar_ 44125 Tempe B5282 (F'no_a_x) 2400