903908 - 12-31-01.qxd 2/13/02 2:30 PM Page 1 ESPAÑOL: PÁGINA 13 FRANÇAISE : PAGE 25 Instruction manual FINISH NAILER MODEL FN250B To learn more about Porter-Cable visit our website at: http://www.porter-cable.com IMPORTANT Please make certain that the person who is to use this equipment carefully reads and understands these instructions before starting operations. The Model and Serial No. plate is located on the main housing of the tool.
903908 - 12-31-01.qxd 2/13/02 2:31 PM Page 2 PORTER✦CABLE Porter-Cable Corporation 4825 Highway 45 North Jackson, TN 38305 Matthew G.
903908 - 12-31-01.qxd 2/13/02 2:31 PM Page 3 GENERAL SAFETY RULES DANGER: When using pneumatic tools, basic safety precautions should always be followed to reduce the risk of personal injury, including the following: READ AND FOLLOW ALL INSTRUCTIONS. There are certain applications for which this tool was designed. Porter-Cable strongly recommends that this tool NOT be modified and/or used for any application other than for which it was designed.
903908 - 12-31-01.qxd 2/13/02 2:31 PM Page 4 7. Wear ear protection to safe-guard against possible hearing loss. Fig. 5. 8. Use clean, dry, regulated, compressed air at 70 to 120 PSI, (4.8 to 8.3 BAR). Fig. 6. 9. Do not connect tool to pressure which potentially exceeds 200 PSI (13.7 BAR). 10. Only use air hose that is rated for a maximum working pressure of at least 150 PSI (10.3 BAR) or 150% of the maximum system pressure, which ever is greater. 11.
903908 - 12-31-01.qxd 2/13/02 2:31 PM Page 5 Fig. 11 Fig. 12 21. Remove finger from trigger when not driving fasteners. Never carry tool with finger on trigger: tool will fire a fastener if safety is bumped while trigger is depressed. Fig. 14. 22. Do not overreach. Keep proper footing and balance at all times when using or handling the tool. 23. Fire fasteners into work surface only: never into materials too hard to penetrate. Fig. 15. 24.
903908 - 12-31-01.qxd 2/13/02 2:31 PM Page 6 TECHNICAL SPECIFICATIONS Noise level . . . . . . . . . . . . . . . . . . A - Weighted sound impulse . . . power level . . . . . . . 96 dBA P - Emission sound pressure pressure level . . . . . . 89 dBA Typical Mean effective Acceleration . . . . . . 3 m/s2 EMPLOYER’S RESPONSIBILITIES DANGER: Employer must enforce compliance with the safety warnings and all other instructions contained in this manual.
903908 - 12-31-01.qxd 2/13/02 2:31 PM Page 7 PREPARING THE TOOL 1. After reading and understanding this entire manual, connect tool to air supply (Fig. 18). DANGER: Never point tool at yourself or others in work area. • Always connect tool to air supply before loading fasteners (Fig. 18). • Do not load fasteners with trigger or safety depressed. • Only use approved Porter-Cable fasteners. • Operator and others in work area MUST wear safety glasses with side shields. Always wear ANSI Z87.
903908 - 12-31-01.qxd 2/13/02 2:31 PM Page 8 5. Adjust directional exhaust deflector (A) Fig. 22, so that the exhaust air blast will be directed away from the operator. The exhaust deflector provides eight detented positions for directing the exhaust blast away from the operator. Grasp the deflector and rotate it to the desired position for the current application. Fig.
03908 - 12-31-01.qxd 2/13/02 2:31 PM Page 9 WARNING: Disconnect tool from Fig. 23 air supply before performing maintenance, clearing a jammed fastener, leaving work area, moving tool to another location, A or handing the tool to another person. WARNING: Clean and inspect tool daily. Carefully check for proper operation of trigger and safety mechanism. Do Not use the tool unless both the trigger and the safety mechanism are functional, or if the tool is leaking air or needs any other repair.
903908 - 12-31-01.qxd 2/13/02 2:31 PM Page 10 MAINTENANCE CLEAN AND INSPECT DAILY WARNING: Disconnect tool from air supply before cleaning and inspection. Correct all problems before placing the tool back in use. Wipe tool clean and inspect for wear or damage. Use non-flammable cleaning solutions to wipe exterior of tool only if necessary. DO NOT SOAK tool with cleaning solutions. Such solutions can damage internal parts.
903908 - 12-31-01.qxd 2/13/02 2:31 PM Page 11 ACCESSORIES A complete line of accessories is available from your Porter-Cable • Delta Supplier, Porter-Cable • Delta Factory Service Centers, and Porter-Cable Authorized Service Stations. Please visit our Web Site www.porter-cable.com for a catalog or for the name of your nearest supplier. WARNING: Since accessories, other than those offered by Porter-Cable • Delta, have not been tested with this product, use of such accessories could be hazardous.
903908 - 12-31-01.qxd 2/13/02 2:31 PM Page 12 PORTER-CABLE LIMITED ONE YEAR WARRANTY Porter-Cable warrants its nailing and stapling tools for a period of one year from the date of original purchase. We will repair or replace at our option, any part or parts of the product and accessories covered under this warranty which, after examination, proves to be defective in workmanship or material during the warranty period.
903908 - 12-31-01.
Attachments & accessories: • Exceeding the pressure rating of air tools, • Follow the equipment manufacturers spray guns, air operated accessories, recommendation and never exceed the tires, and other inflatables can cause maximum allowable pressure rating of them to explode or fly apart, and could attachments. Never use compressor to result in serious injury. inflate small low pressure objects such as children’s toys, footballs, basketballs, etc.
DUTY CYCLE FIG. 1 A This air compressor pump is capable of running continuously. However, to prolong the life of your air compressor, it is recommended that a 50%-75% average duty cycle be maintained; that is, the air compressor pump should not run more than 30-45 minutes in any given hour. C ASSEMBLY B Unpacking Remove unit from carton and discard all packaging. FIG.
SERVICE AND REPAIRS All quality tools will eventually require servicing and/or replacement of parts. For information about PORTER-CABLE, its factory service centers or authorized warranty service centers, visit our website at www.deltaportercable.com or call our Customer Care Center at 1-(888)-8485175. All repairs made by our service centers are fully guaranteed against defective material and workmanship. We cannot guarantee repairs made or attempted by others.
• Utiliser le compresseur avec des pièces • Toutes les réparations requises pour ce endommagées ou manquantes ou le produit devraient être effectuées par un réparer sans coiffes de protection risque centre de réparation de un centre de de vous exposer à des pièces mobiles et réparation autorisé. peut se solder par de graves blessures.
ENTRETIEN ET RÉGLAGES Garantie complète d’un (1) an TOUS LES SERVICES D'ENTRETIEN NE FIGURANT PAS ICI DOIVENT ÊTRE EXÉCUTÉS PAR UN TECHNICIEN QUALIFIÉ. Les outils industriels de PORTER-CABLE sont garantis pour une période de un (1) an à partir de la date d’achat. PORTER-CABLE réparera gratuitement toutes défectuosités provoquées par un défaut de matériel ou de fabrication. Pour des renseignements relatifs aux réparations sous garantie, composer le 1-(888)-848-5175.
PELIGRO Ramal: Circuito eléctrico que transporta electricidad desde el panel de control hasta el tomacorriente. CICLO DE SERVICIO riesgo de descarga eléctrica ¿Qué puede suceder? Cómo evitarlo • Su compresor de aire funciona con • Nunca haga funcionar el compresor al electricidad. Como cualquier otro aire libre cuando está lloviendo o en mecanismo que funciona con electricidad, condiciones de humedad.
Cómo poner en marcha 1. Coloque la posición de la llave interruptora On/Off (D) en la posición "Off" y deje que se incremente la presión del tanque. El motor se detendrá una vez alcanzado el valor de "presión de corte" del tanque. 2. Gire la perilla del regulador (G) en el sentido del reloj para aumentar la presión y deténgase al alcanzar la presión deseada. Si observa algún ruido o vibración inusuales, apague el compresor y contacte a un técnico calificado en servicio.