Installation Guide
1.
Remove both finial caps (BB) by unscrewing
counterclockwise. Remove the diffuser (C) to expose the
bulbs.
BULB REPLACEMENT INSTRUCTIONS
You may want to periodically clean the fixture using a mild, non-abrasive soap based cleaner and
soft cotton cloth. Do NOT use solvents, cleaners containing abrasive agents, ammonia, or
surfactants. When cleaning the fixture, make sure you have the power turned off and do not spray
liquid cleaner directly onto the diffuser, bulb, socket, ballast, or wiring.
CARE AND MAINTENANCE
When bulb replacement is necessary, you must replace the bulb with a 17-watt, 120-volt/F17T8 fluorescent
bulb. These bulbs are readily available at your local home center and most larger hardware stores.
Before replacing the bulb(s), shut off power to the fixture at the circuit breaker or fuse panel. Allow
sufficient time for fixture and lamp to cool.
3. Install the new bulb in the same manner you removed
the old bulb.
Re-install the diffuser (C) and finial caps (BB). Restore power to the fixture.
4. Dispose of the old bulb(s) in accordance with local, state, and/or federal laws, or go to
www.epa.gov/cflcleanup for more information.
2. Remove the defective bulb by
using your thumbs to
press and roll the bulb 90 degrees inside the
socket
(B)
. This will disengage the bulb contact pins from
the socket
(B)
contacts. Then slide the bulb pins out of the
socket
(B)
slot.
Minor problems often can be fixed without the help of an electrician. Before doing any work on the
fixture, shut off power supply at the circuit breaker panel to avoid electrical shock.
TROUBLESHOOTING
Fixture doesn’t light.
Circuit breaker trips
when light is turned on.
1. Power is off.
2. Bad wire connection.
3. Defective bulb(s).
4. Defective wall switch.
1. Crossed wires or power wire
is grounded out.
1. Check circuit breaker or wall switch.
2. Check wire splices.
3. Replace bulb(s).
4. Replace switch.
1. Check wiring connections.
In the unlikely event that your fixture’s ballast or lamp socket(s) fail, they can be replaced by a
qualified electrician. For further information regarding these replaceable parts, please have your
electrician contact our technical support number at 1-800-643-0067.
PROBLEM POSSIBLE CAUSE CORRECTIVE ACTION
B
1
A
6