User's Manual

16
(6) AD detect report (AD2)
[on/off] SEND REPORT IF ADC2 LESS THAN [min voltage] V for [debounce time] SEC, RESEND PER
[resend time] SEC
[on/off] SEND REPORT IF ADC2 MORE THAN [max voltage] V for [debounce time] SEC, RESEND PER
[resend time] SEC
[on/off] SEND REPORT IF ADC2 GO UP [up voltage] V for [debounce time] SEC
[on/off] SEND REPORT IF ADC2 GO DOWN [down voltage] V for [debounce time] SEC
[on/off] SEND REPORT IF ADC2 ENTER/EXIT [min voltage] V TO [max voltage] V for [debounce time]
SEC
Note: AD2 input voltage range is 0~3.30v, it must connect a resistance to share the voltage if the detected
voltage higher than 3.30v.
(7) Fixed time report
Parameters: On/Off, and time.
(8) Fixed distance report
Parameters: On/Off, and distance. (min. distance is 0.1 km, max. distance is 100 km).
(9) Course change report (to send a report when the course change is bigger than the value set here)
Parameters: On/Off, course change in degree and debounce time.
(10) Low battery warning report (to alert user when the external battery level is low)
Parameters: On/Off, and warning battery level for report. For example, 50 to represent 50% lower level
report.
The system will ignore the parameter with a value ‘0’ to prevent continuous non-stop reporting.
(11) Speed report
Parameters: resend interval, threshold speed, over speed delay time, exit over speed delay time, alert when
over speed and report send or ignore
For example, if resend interval is 20 sec, enter over speed delay time is 20 sec, threshold speed is 110Km/h
and exit over speed delay time is 2 sec.
If vehicle speed over threshold speed 20seconds, system will send speed over report once interval 20 sec
until exit speed over delay time 2 sec, the over speed report will stop to send. If alert when over speed has
configured, then it will alert when speed over.
(12) Crash report
Parameters: on/off, and speed