User's Manual

20
5. [Alarm REPORT setup]
Alarm report(s) is also configurable. User can customize the events generated by the in-vehicle input or
build in car alarm to be sent to the server. If the item(s) be selected (VALID), the related reports will be sent.
Otherwise the report will be ignored even when an event is occurred internally.
Also build in car alarm function can be set on here.
If input 3 with distance is selected, system will send the distance report every time ACC ON to ACC OFF, for
example: %%GT3200ST,A,070521024400,N2240.8929E11359.2030,000,270,NA,D7000000,254,CFG:5, CFG:5
means the current ACC ON to ACC OFF distance is 5km.
Sleep mode (when ACC OFF)
(1) GT3200ST can go to sleep mode when ACC goes off and crash-sensor (and optional shock sensor) not
be trigger for 5minuts. In sleep mode, GPS will be disabled.
All the auto report (Time, Distance, Intelligent…) will not be send when ACC goes off.
(2) During the sleep mode, the system can wait up automatically and send a wake up diagnostic report. The
automatic wakeup time is configurable. (Minimum duration is 5 minutes; maximum duration is 1000
Hours).
(3) If any of the inputs are triggered while in the sleep mode, the system will wake up automatic and then
send reports to the server. The input triggers for waking the device up are selectable. If the GPRS connection
is failed, for emergency purpose, GT3200ST will send out SMS report if number is defined.
If select the item, when ACC off, system will cut power of handset, otherwise, system will not cut power of
handset.