User's Manual

2
The event trigger report is also configurable. User can turn on or off any event generated report from the PC
setup program or via the air command. The event triggered report include (1) In-vehicle Door close/open (2)
In-vehicle ignition on/off (3) Temperature range in/out the preset range (4) In-vehicle shock sensor trigger.
The build in alarm (optional) trigger reports are also configurable and can be set from PC setup program or
air command.
The server can not only configure the device just like the PC setup program does, but it also can send the
command to control the device. The server can control both the device and the build in alarm.
1.3 Geofence function
The device has built-in 30 Geofence sets (1 immediate geofence, 4 circular, 5 rectangular and 20 point), it
will send the report to the server if the Geofence event is triggered. User can setup the Geofence area from
the PC setup program or sending the define.
A unique immediate Geofence function:
‘Immediate-Geofence function’ is a circular type Geofence which can be activated or deactivated from a
single button. When activated, the system will record the current position and use the pre-defined radius as a
circular Geofence to guard the vehicle. If the vehicle moves out of the preset Geofence zone, a report will be
generated to the server. User can deactivate the self-Geofence at any time by pressing the button again. If the
GPS cannot be located when the Immediate Geofence function is been executed, GT3200ST will used the
last known position as the origin of the circular Geofence zone to perform the protection.
1.4 Store and forward ability
When there is no GPRS service or the server close. The unit will send short message to the server if defined
SMS number. All the stored report will be forward to the server when GPRS connection is completed next
time.
1.5 TCP and UDP socket support
GT3200ST supports both UDP and TCP socket communication. The server IP, port number and socket type
can be selected from the PC-setup program or remote server command. In addition, the connection can be
swap over to any server IP or port (either UDP or TCP) via the air command.
1.6 The server can send the command to control the device and the build in alarm.
Command for in-vehicle control:
We design 7 commands which can be integrated into the server, so that the users can control their vehicles.
Those commands are: (1) Door lock, (2) Door unlock, (3) Arming, (4) Panic, (5) Enable anti-car jacking, (6)
Emergency release, (7) Trunk output
Notes:
1. Arming (this command is valid only if when ACC is off): If ACC Off, Server send arming command.
The door will lock and the Engine will be Disable starter (if the starter cut relay connected), after the
unit received the command.
2. Panic: (can be performed at any time) If Server send panic command, the horn will sound and parking
lights will flash for 30 seconds after the unit received the command.
3. Enable anti-car jacking: (can be performed at any time) If Server send anti-car jacking command, the
system will enter anti-carjacking mode after the unit received the command. Enter the anti-carjacking