In the working mode, the system will use the configurations as defined in this section. To activate the automatic
report, please select “” in checkbox and fill in data in the textbox.
The reports will be summarized as
(1) Intelligent report
Parameters: On/Off, Report time when moving, Report time when stop, and Moving Speed (min. Speed is 0.1
km/Hr, max. Speed is 1000 km/Hr).
(2) Intelligent history report (record the report in the systems flash ram)
Parameters: On/Off, Report time when moving, Report time when stop, and Moving Speed (min. Speed is 0.1
km/Hr, max. Speed is 1000 km/Hr).
(3) Fixed time report
Parameters: On/Off, and time.
(4) Fixed distance report
Parameters: On/Off, and distance. (min. distance is 0.1 km, max. distance is 100 km).
(5) Course change report
Parameters: On/Off, and course change in degree.
(6) Low battery warning report (to alert user when the battery level is low)
Parameters: On/Off, and warning battery level for report. For example, 60 to represent 60% lower level report.
The system will ignore the parameter with a value ‘0’ to prevent continuous non-stop reporting.
Power cut report: default is on. When the external power is cut, a POWER CUT report will be sent to the
server.
(7) Speeding report: (min. speed is 0.1 km/Hr, max. speed is 1000 km/Hr).
Parameters: on/off, and speed
4.[Trigger report and sleep mode setup]