User's Manual

33
J2-12. C
HANNEL 3 OUTPUT MODE SELECT
Pre-set: Momentary output: Anytime, within 3 seconds press button 4 once then press
button 3 once, CH3 will output-300 mA
Variable1: Latched output: this selection will output a –300mA signal from the channel 3
output as soon as the channel 3 button is pressed and will continue until the button is
pressed again.
Variable2: Latched output/reset with ignition ON: this selection will output a –300mA
signal from the channel 3 output as soon as the channel 3 button is pressed but will reset or
stop when the ignition is turned ON.
Variable3: 30 seconds output: this selection will continue output a 30 seconds –300mA
signal from the channel 3 output as soon as the channel 3 button is pressed.
J2-13.C
HANNEL 4-OUTPUT MODE SELECT
Pre-set: Momentary output: Anytime, within 3 seconds press button 4 once then press
button 4, CH4 will output -300 Ma.
Variable1: Latched output: this selection will output a –300mA signal from the channel 4
output as soon as the channel 4 button is pressed and will continue until the button is
pressed again.
Variable2: Latched output/reset with ignition ON: this selection will output a –300mA
signal from the channel 4 output as soon as the channel 4 button is pressed but will reset or
stop when the ignition is turned ON.
Variable3: 30 seconds output: this selection will continue output a 30 seconds –300mA
signal from the channel 4 output as soon as the channel 4 button is pressed.
J2-14. D
EFAULT SETTING
Pre-set: Return the feature menu 2 to the factory set-up.