Datasheet
Printed at 11-06-2015 23:06
- 1 -
IXARC Rotary Encoder
MCD-AVP02-0012-M100-PRM
Interface
Interface Analog Voltage
Manual Functions Programmable Start and End point via Cable or
Connector or Push Button
Outputs
Electrical Data
Supply Voltage 12 – 30 VDC (On power supplies comply with EN 50178)
Current Consumption Typical 15 mA
Start-Up Time < 250 ms
Min. Load Resistance 10 KΩ (Min. value for supply voltage 12 V. For higher
supply voltage lower load resistances can be used)
Linearity 0.15%
Analog Accuracy @ 5V = ± 15 mV; @10 V = ±25 mV
Settling Time 80 ms
Reverse Polarity Protection Yes
Short Circuit Protection Yes
EMC: Emitted Interference DIN EN 61000-6-4
EMC: Noise Immunity DIN EN 61000-6-2
MTTF 262.2 years @ 40 °C
Sensor
Technology Magnetic
Resolution Singleturn 12 bit
Accuracy (INL) ±0.36°
Sense Signal (Default) Counterclockwise shaft movement (front view on shaft)
Code Analog Voltage 0 – 10 V
Minimum Measurement Range 0 – 22.5°
Resolution of Output Max. 12 bits over entire measureing range (Fractional
Turns - Resolution decreases less than 12 bits when
measurements range is less than 90 degrees)
Multiturn Range Singleturn
Environmental Specifications
Protection Class (Shaft) IP65
Protection Class (Housing) IP65