Datasheet

Printed at 11-06-2015 16:06
- 1 -
IXARC Rotary Encoder
OCD-DPC1B-1416-S06S-H3P
Interface
Interface Profibus DP
Profile DPV0, DPV1 and DPV2 Class 2 (EN50170 + EN50254)
Diagnostics Memory
Programming Functions Resolution, gearing factor (physical resolution) , velocity
scaling + filter, preset (zero point), counting direction,
limit switches , node number, teach-in, diagnosis
Manual Functions Address selector switch 0-99 and terminal resistor (with
connection cap)
Transmission Rate ≤12 Mbaud
Interface Cycle Time > 1 ms
Outputs
Output Driver Profibus Data Interface, galvanically isolated via
opto-couplers
Electrical Data
Supply Voltage 10 – 30 VDC (On power supplies comply with EN 50178)
Current Consumption ≤ 230 mA @ 10 V DC, ≤ 100 mA @ 24 V DC
Power Consumption ≤ 2.5 W
Start-Up Time < 1 s
Reverse Polarity Protection Yes
Short Circuit Protection Yes
EMC: Emitted Interference DIN EN 61000-6-4
EMC: Noise Immunity DIN EN 61000-6-2