Manual POSline SC2120/SC2130/SC2140 1D & 2D Barcode Reader User's
NOTICE: A letter to Our Customers This device complies with Part 15 of the FCC Rules. Operation shall Dear Customers, be subject to the following two conditions: (1) This device may not cause harmful interface, and Congratulation on selecting our Scanner! We believe you will immediately find that you have already made the smartest (2) This device must accept any interface received, including interface that may cause undesirable operation. choice! This booklet is a small gift from us.
Using the POSline SC2120/SC2130/SC2140 CONTENTS The SC2120/SC2130/SC2140 can automatically scan barcode at a distance. Simply aim and pull the trigger. Code scanning is performed along the center of the light bar emitted from the reading window. This bar must cover the entire code. Successful scanning shall be obtained by tilting the scanner with respect to the barcode to avoid direct reflections that impair the reading performance, especially for 2D barcode .
UK/Plessey ………………………………………….. ………………… 65 Telepen …………………………………………………………………… 67 Standard 2 of 5 …………………………………………………………… 69 RSS-14 …………………………………………………………………… 71 RSS-Limited ……………………………………………………………… 73 RSS-Expanded …………………………………………………………… 75 China Post ………………………………………………………………… 77 Italian pharmacode ……………………………………………………… 79 Code 16K …………………………………..
Default Setting for each barcode shown as below: Introduction Installation- Keyboard Wedge 1) First of all, you must switch off the terminal/computer. 2) Disconnect the keyboard cable from the back of the terminal/computer. 3) Connect the appropriate interface cable to the scanner and to the 1) Disconnect power to the terminal/computer.
POSline SC2120/SC2140 - 1D Barcode scanner Weight Specification Cable – K/B wedge Straight 2.0 m Cable – universal type Straight 2.
Programmable Code type selection, check digit selection Decoding POSline SC2130 - 2D Barcode scanner characteristics option Decoding option Transmitted character delay, Specification Header selection, trailer selection, message suffix, good read beep tone and volume, scanner trigger selection Keyboard emulation type (intermessage delay, Operational Light Source 660 nm Visible Red LED Optical System 2048 pixel CCD (charge-coupled device) keyboard type and keyboard language).
Cushion material Rubber Electrical Programmable Code type selection, check digit selection Decoding characteristics option Decoding option Transmitted character delay, 5 VDC ± 0.
Program Barcode Programming the POSline SC2120/SC2130/SC2140 Program To program the SC2120/SC2130/SC2140, you must scan a series of programming barcode in the correct order. Fold out the back cover of this manual. You will see a table of alphanumeric barcodes, which are used to program the various Option Bar Code Option Alphanumeric Entry Keyboard Wedge 00* Interface RS-232 01 selection Wand emulation 02 1. Scan the Program barcode on the parameter setting part. USB 03 2.
Interface Selection Keyboard wedge This decoder build-in scanner comes in one model and supports interfaces such as keyboard wedge, RS232 serial wedge, wand emulation, and the latest USB interface. In most of the cases, simply selecting an appropriate cable with a device code will work for a specific interface. Interface selection: You can change factory interface default for other type interface. By plugging different cables, setting right interface, then the scanner will be changed to another interface.
Keyboard wedge Italian 05 Portuguese 06 Spanish 07 Swedish 08 “Keyboard” to select country at “language” item. For details, please refer to your Switzerland 09 DOS or WINDOWS user’s manual. UK 10 Keyboard Speed: By selecting, you can change output speed of scanner to Latin American 11 match with host computer. Generally, set 00 or 01 in working high speed.
Keyboard wedge Program Caps Lock: By selecting Caps Lock or No Caps Lock, scanner can get Caps Lock status. Option Bar Code Power-on simulation: All of the PCs check the keyboard status during power-on selftest. It is recommended to Enable function if you are working without keyboard installation. It simulates keyboard timing and pass keyboard Alphanumeric Entry Caps lock”ON” 00 Caps lock”OFF” 01* Disable 00* Enable 01 00-99 msec 00-99 Caps lock present status to the PC during power-on.
RS-232 Program CTS: Clear To Send (Hardware Signal) RTS: Request To Send (Hardware Signal) Option Bar Code Option Xon: Transmit On (ASCII Code 1116) Xoff: Transmit Off (ASCII Code1316) Flow control: None-The communication only uses TxD and RxD signals without regard for Flow control any hardware or software handshaking protocol.
Wand Emulation Program Option Bar Code Option Alphanumeric Entry Bar/space polarity: High/low- Black will be transmitted as a high voltage level (+5) and space as Baud rate Parity 300 BPS 00 low level (0V). 600 BPS 01 Low/high- Black will be transmitted as a low voltage level (0V) and space as 1200 BPS 02 2400 BPS 03 4800 BPS 04 9600 BPS 05* 19200 BPS 06 38400 BPS 07 None 00* Odd 01 Even 02 8 bits 00* 7 bits 01 high level (+5).
Wand Emulation Program Output speed: This setting is same as serial transmission baud rate, and it Option Bar Code Option Alphanumeric Entry must be approbated your wand decode resolution. The unit of speed is a width of minimum narrow bar. 620 pps 00 1250 pps 01 2500 pps 02 5000 pps 03* 10000 pps 04 20000 pps 05 Margin delay: It is a timer of zone like space zone of barcode label margin.
Scan Program Scanning mode: Good-read off-The trigger button must be pressed to activate scanning. The Option Bar Code Option Alphanumeric Entry light source of scanner stops scanning when there is a successful reading or no Good-read off 00 Momentary 01* Alternate 02 stop scanning. Timeout off 03 Timeout off-The trigger button must be pressed to activate scanning, and Continue 04 01-99 (second) 00-99 code is decoded after the Stand-by duration elapsed.
Scan 00-63 Multi field scan: The scanner can be read many sets of barcode data on the 04* same scanning line at the same time, even if they are different kinds of barcode symbology. 00-63 Global min. code length 00-63 Global min./max. code length: Global Minimum and Maximum length can be 63* set to qualify data entry. The length is defined as the actual barcode data length to be sent. Label with length exceeds these limits will be rejected. Make sure 04-63 Global max.
Indication Program Power on alert: After power-on the scanner it will generate an alert signal to indicate a successful self-test. Option Bar Code LED indication: After each successful reading, the LED above the scanner will light up to indicate a good barcode reading.
UPCA Read: Format Leading Data Digits Check Zero (11 Digits) Digit Disable 00 Enable 01* Disable 00 Enable 01* 00-64 00-64 Check-sum verification Check-sum transmission: By setting Enable, checks sum will be transmitted. Check-sum transmission Truncate leading/ending: The leading or ending digits of barcode data characters can be truncated when these values are set to non-zero.
UPCA UPCE Supplement digits: The Supplement digits barcode is the supplemental 2 or 5 Read: Format characters for WPC code. Leading Zero Data Digits (6 Digits) Check Digits Format Leading Data Digits Check Zero (11 Digits) Digit Supplement Digits 2 or 5 or Check-sum verification: The checksum of EAN-13 is optional and made as the sum of the numerical value of the data digits. UCC / EAN 128 Check-sum transmission: By setting Enable, checks sum will be transmitted.
UPCE 00-ffH ASCII code 00-ffH < E >* Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code ID setting Code Id setting: Refer to Code ID setting of UPCA. 00-44 00-44 00* Insertion group selection: Refer to Insertion group selection of UPCA. Insert group selection Supplement digits: Format None 00* 2 digits 01 5 digits 02 Truncate Leading zero: Refer to Truncate Leading zero of UPCA.
EAN-13 Read: Format Data Digits (12 Digits) Check Digits Disable 00 Enable 01* 00-64 00-64 Check-sum transmission Check-sum verification: The checksum of EAN-13 is optional and made as 64* the sum of the numerical value of the data digits. Max.code length Check-sum transmission: By setting Enable, checks sum will be transmitted. 00-64 01* Max./Min. code length: Each symbology has own Max./Min. Code Length. They can be set to qualify data entry. If their Max./Min.
EAN-13 Program Code Id setting: Refer to Code ID setting of UPCA. Option Bar Code Option Alphanumeric Entry Insertion group selection: Refer to Insertion group selection of UPCA.
EAN-8 00-64 00-64 01* Read: Format Data Digits Check (7 Digits) Digits Min.code length 0-15 Check-sum verification: The checksum of EAN-8 is optional and made as the 00-15 00* sum of the numerical value of the data digits. Check-sum transmission: By setting Enable, checks sum will be transmitted. Truncate leading Max./Min. code length: Refer to Max./Min. code length of EAN-13. 0-15 Truncate leading/ending: Refer to Truncate leading/ending of UPCA.
EAN-8 Code 39 Supplement digits: Format Read: Format Data Digits Check (7 Digits) Digits Supplement Digits 2 or 5 or Start Data Digits Checksum End UCC/EAN 128 “★” ( Variable) (Optional) “★” Check-sum verification: The checksum of Code-39 is optional and made as Truncate Leading zero: Refer to Truncate Leading zero of UPCE. the sum module 43 of the numerical value of the data digits. Expansion: Refer to Expansion of UPCE.
Code 39 0-15 00-15 00* Max./Min. code length: Each symbology has own Max./Min. Code Length. They can be set to qualify data entry. If their Max./Min. Code Length is zero, the Truncate leading Global Min./Max. Code Length is in effect. The length is defined as to the actual 0-15 barcode data length to be sent. Label with length exceeds these limits will be 00-15 00* rejected.
Code 39 Interleaved 2 of 5 Append: This function allows several symbols to be concatenates and be treat Read: Format as one single data entry. The scanner will not transmit the embedded Data Digits (Variable) Checksum (Optional) appending code (space for Code-39). If Enable and other symbols were read again with the appended code, then codes will be transmitted without Code ID, Check-sum verification: The checksum is made as the sum module 10 of the Preamble and Prefix.
Interleaved 2 of 5 Program Max./Min. code length: Refer to Max./Min. code length of Code-39. Option Bar Code Option Alphanumeric Entry Truncate leading/ending: Refer to Truncate leading/ending of UPCA. 00-64 00* Code Id setting: Refer to Code ID setting of UPCA. Insertion group selection: Refer to Insertion group selection of UPCA. 00-64 Max. code leading 00-64 00-64 00* Min.
Industrial 2 of 5 0-15 00-15 00* Read: Format Data Digits Checksum (Variable) (Optional) Truncate ending 00-ffH ASCII code 00-ffH < i >* Max./Min. code length: Refer to Max./Min. code length of Code-39. Code ID setting Truncate leading/ending: Refer to Truncate leading/ending of UPCA. 00-44 00-44 00* Code Id setting: Refer to Code ID setting of UPCA. Insertion group selection: Refer to Insertion group selection of UPCA.
Matrix 2 of 5 Eur Read: Format Data Digits Checksum (Variable) (Optional) Disable 00* Enable 01 00-64 00-64 Checksum Transmission 00* Checksum Verification: The checksum is made as the sum module 10 of the numerical values of all data digits. Max. code length 00-64 Checksum Transmission: By setting Enable, checksum and will be 00-64 00* transmitted. Max./Min. code length: Refer to Max./Min. code length of Code-39. Min.
Codabar 00-64 00* Read: Format Start 00-64 Data Digits (Variable) Checksum (Optional) End Max. code length 00-64 Checksum Verification: The checksum is made as the sum module 16 of the 00-64 00* numerical values of all data digits. Min. code length Checksum Transmission: By setting Enable, checksum and will be 0-15 transmitted. 00-15 00* Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading 0-15 Truncate leading/ending: Refer to Truncate leading/ending of UPCA.
Codabar Code-128 Insertion group selection: Refer to Insertion group selection of UPCA. Read: Format Start/End type: The Codabar has four pairs of Start/End pattern; you may Data Digits Checksum (Variable) (Optional) select one pair to match your application. Checksum Verification: The checksum is made as the sum module 103 of all Start/End Transmission: Refer to Start/End Transmission of Code 39. data digits. Checksum Transmission: By setting Enable, checksum and will be transmitted.
Code-128 0-15 00-15 Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. 00* Truncate leading 0-15 Code Id setting: Refer to Code ID setting of UPCA. 00-15 00* Insertion group selection: Refer to Insertion group selection of UPCA. Truncate ending 00-ffH ASCII code Format: The Code-128 can be translated to UCC/EAN-128 format if it starts with FNC1 character.
Code-93 Read: Format Data Digits Checksum1 Checksum2 (Variable) (Optional) (Optional) Disable 00* Enable 01 00-64 00-64 Checksum Transmission Checksum Verification: The checksum is made as the sum module 47 of the numerical values of all data digits. 00* Checksum Transmission: By setting Enable, checksum and will be Max. code length transmitted. 00-64 00* Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA.
Code-11 00-64 00-64 00* Read: Format Data Digits Checksum1 Checksum2 (Variable) (Optional) (Optional) Max. code length 00-64 00* Checksum Verification: The checksum is presented as the sum module 11 of all data digits. 00-64 Min. code length 0-15 Checksum Transmission: By setting Enable, checksum1 and checksum2 will 00-15 00* be transmitted upon your selected checksum verification method. Max./Min. code length: Refer to Max./Min. code length of Code-39.
MSI/plessey Read: Format Data Digits Checksum1 Checksum2 (Variable) (Optional) (Optional) Disable 00* Enable 01 00-64 00-64 Checksum Transmission 00* Checksum Verification: The MSI/Plessey has one or two optional checksum digits. The checksum is presented 3 kinds of method Mod10, Mod10/10 and Mod 11/10. Max. code length The checksum1 and checksum2 will be calculated as the sum 00-64 module 10 or 11 of the data digits.
UK/plessey 00-64 00-64 00* Read: Format Data Digits Checksum1+2 (Variable) (Optional) Max. code length 00-64 00* Checksum Verification: The UK/Plessey has one or two optional checksum digits. The checksum1 and checksum2 will be calculated as the sum module 10 00-64 Min. code length or 11 of the data digits. 0-15 00-15 00* Checksum Transmission: By setting Enable, checksum will be transmitted. Max./Min. code length: Refer to Max./Min. code length of Code-39.
Telepen 00-64 00-64 00* Read: IATA (International Air Transport Association). Max. code length Checksum Verification: The checksum is presented as the sum module 10 or 00-64 11 of the data digits. 00-64 00* Checksum Transmission: By setting Enable, checksum will be transmitted. Min. code length 0-15 Max./Min. code length: Refer to Max./Min. code length of Code-39. 00-15 00* Truncate leading/ending: Refer to Truncate leading/ending of UPCA.
Standard 2 of 5 0-15 00-15 00* Read: Format Data Digits Checksum1 (Variable) (Optional) Truncate ending 00-ffH ASCII code 00-ffH < i >* Max./Min. code length: Refer to Max./Min. code length of Code-39. Code ID setting Truncate leading/ending: Refer to Truncate leading/ending of UPCA. 00-44 00-44 00* Code Id setting: Refer to Code ID setting of UPCA. Insertion group selection: Refer to Insertion group selection of UPCA.
RSS-14 0-15 00-15 00* Read: Format Data Digits Checksum1 (Variable) (Optional) Truncate leading 0-15 Max./Min. code length: Refer to Max./Min. code length of Code-39. 00-15 00* Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Truncate ending 00-ffH ASCII code Code Id setting: Refer to Code ID setting of UPCA. 00-ffH < R4 >* Insertion group selection: Refer to Insertion group selection of UPCA.
RSS-Limited 0-15 00-15 00* Read: Format Data Digits Checksum1 (Variable) (Optional) Truncate ending 00-ffH ASCII code 00-ffH < RL >* Max./Min. code length: Refer to Max./Min. code length of Code-39. Code ID setting Truncate leading/ending: Refer to Truncate leading/ending of UPCA. 00-44 00-44 00* Code Id setting: Refer to Code ID setting of UPCA. Insertion group selection: Refer to Insertion group selection of UPCA.
RSS-Expanded 0-15 00-15 00* Read: Format Data Digits Checksum1 (Variable) (Optional) Truncate leading 0-15 00-15 00* Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate ending Truncate leading/ending: Refer to Truncate leading/ending of UPCA. 00-ffH ASCII code 00-ffH < RX >* Code Id setting: Refer to Code ID setting of UPCA. Insertion group selection: Refer to Insertion group selection of UPCA.
China Post 00-15 0-15 00* Read: Format Data Digits Checksum1 (Variable) (Optional) Truncate ending 00-ffH ASCII code 00-ffH < t >* Max./Min. code length: Refer to Max./Min. code length of Code-39. Code ID setting Truncate leading/ending: Refer to Truncate leading/ending of UPCA. 00-44 00- 44 00* Code Id setting: Refer to Code ID setting of UPCA. Insertion group selection: Refer to Insertion group selection of UPCA.
Italian Pharmacode 00-15 0-15 00* Read: Format Data Digits Checksum1 (Variable) (Optional) Truncate ending 00-ffH ASCII code 01-ffH < p >* Max./Min. code length: Refer to Max./Min. code length of Code-39. Code ID setting Truncate leading/ending: Refer to Truncate leading/ending of UPCA. 00-44 00-44 00* Code Id setting: Refer to Code ID setting of UPCA. Insertion group selection: Refer to Insertion group selection of UPCA.
Code-16K PDF-417 Only the SC2130 can decode Code-16K. Only the SC2130 can decode PDF-417. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code Id setting: Refer to Code ID setting of UPCA. Code Id setting: Refer to Code ID setting of UPCA. Insertion group selection: Refer to Insertion group selection of UPCA. Insertion group selection: Refer to Insertion group selection of UPCA.
String setting Prefix characters: Up to 22 ASCII characters may be sent before data digits. Prefix Data Digits None 00* 1-22 characters 00-ffH ASCII code None 00* 1-22 characters 00-ffH ASCII code None 00* 1-22 characters 00-ffH ASCII code None 00* 1-22 characters 00-ffH ASCII code None 00* 1-22 characters 00-ffH ASCII code Postamble characters Suffix setting Suffix characters: Up to 22 ASCII characters may be sent after data digits.
String setting Program Insert G1/G2/G3/G4 character setting: The scanner offer 4 positions and 4 characters to insert among the symbol. Example: Barcode “1 2 3 4 5 6”. Option Bar Code Option Output- Barcode “1 2 A B 3 4 C D 5 6”. Steps: 1) Scan Programming and Insert G1 characters setting barcode. 2) Use the ASCII code table to find the value of A→41,B→42. 3) Scan 4, 1 and 4, 2 from the barcode on the fold out back page.
Transmission 00-64 00-64 (00: no insertion) 00* 00-64 00-64 (00: no insertion) 00* the symbol. The position default value is “00” to indicate no character insertion. 00-64 00-64 Beside, make sure insertion positions are not greater than the symbols; (00: no insertion) 00* Before code data 00* After code data 01 Preamble transmission: By setting Enable, Preamble will be appended before the data transmitted.
Transmission Code ID transmission: If your application is needed to transmit Code ID, you must set this to Proprietary ID or AIM ID. Case conversion 00* Upper case 01 Lower case 02 *For barcode data only Code length transmission: A number of data digits can be transmitted before the code data when Enable is selected. Disable The total length of the barcode is the number of barcode data except Truncate Leading/Ending Digits. And the length is a number with two digits.
PDF-417 PDF-417 Test Chart CODABAR-PARA STANDRAD-25 PARA CODE-11 PARA CODE-16K CODE-128 PARA COde-128 PARA 87549 EAN-8 PARA CODE-39 PARA INDUSTRIAL-25 PARA CODE-93 PARA UPCE PARA EAN-13 PARA EAN-13 PARA 91 92
INTERLEAVED-25 PARA ASCII Code Table L H 0 0 MATRIX 25 25 PARA IMATRIX PARA Note: 1 Null L UK/PLESSEY PARA 93 0 1 NUL DLE Up F1 SOH DC1 2 Down F2 STX DC2 3 Left F3 ETX DC3 4 Right F4 EOT DC4 5 PgUp F5 ENQ NAK 6 PgDn F6 ACK SYN F7 BEL ETB F8 BS CAN 8 Bs 9 Tab A UPCA PARA UPCA PARA Example: ASCII “A”=“41” 1 7 MSI/PLESSEY PARA MSI/PLESSEY PARA For keyboard wedge only.
Parameter Setting List Program Firmware version list If you wish to display the firmware version, scan the Firmware version list. Barcode standard parameter setting list If you wish to display the current configuration of your scanner over WARNING: Default value initialization the host terminal/computer, scan the Barcode standard parameter setting list default settings, scan the Default value initialization bar code. If you wish to return the scanner to all the factory bar code.
0 A 1 B 2 C 3 D 4 E 5 F 6 7 8 Finish 9 97