Instructions / Assembly

42” – Deck, Pergola, Sunroom, Etc
Installation Instructions - Outdoor Post
1. Slide the Post Protector over the post. The Post Protector should slide easily over the
post & the post’s bottom should contact the bottom of the Post Protector. NOTE: Post
Protector’s are designed to project above grade or finished floor height. Be certain
you are starting with a level building site!
CALL with any installation questions! 877-966-8768
2. (4) 3/8” galvanized lag screws with sealing washers are provided for each post. There
are (2) lag locations located between the “horizontal” ribs on the Post Protector’s
lower section. Continue lag pattern with lag #3 & #4 (see diagram) The lags will join
Post Protector to post to utilize the integral post uplift protection. Pre drill a 1/4”
perpendicular hole through the Post Protector & into the post. Install 3/8” lag and
allow the sealing washer to snug the Post Protector sidewall to the post.
3. Drill out drainage holes dimples. These dimples are centered on all (4) sides of the
base “horizontal” uplift rib. They allow drainage for rainwater running down the post
& through the Post Protector. We suggest 4” 6” drainage stone for initial backfill.
4. Set the post in a typical posthole with desired footing & backfill material.
5. Set your string line “above” the top edge of the Post Protectors to align the posts. Or,
you may also use a roofing nail or screw to draw the Post Protectors firmly &
uniformly against the “outside” of the posts to be sure the string line post alignment
is accurate.
6. Post Protectors will show that your postholes vary in depth. If you want the Post
Protectors at a uniform height, simply measure & mark to desired height. We suggest
4”-6”. Trim by dropping a horizontal sawzall blade on (4) sides, then a vertical cut
with a utility knife to remove excess material.
7. Any unique installation situations or any questions 877-966-8768.