4C INSTALLATION MANUAL d.eps pprove USPS_A 4C MAILBOX SUITES (FRONT LOADING) 500 W. OKLAHOMA AVE. MILWAUKEE, WI 53207 Phone: 800-229-4500 FAX: 800-570-0007 www.postalproducts.
TABLE OF CONTENTS INSTALLATION AND SETUP PAGE GENERAL INFORMATION AND ADVISORIES 2 INSTALLATION REQUIREMENTS 3 PARCEL-ONLY UNIT FUNCTIONALITY AND INSTALLATION INFORMATION 4 INDEPENDENT INSTALLATION 6 INSTALLATION OF COLLECTION DOOR ARROW LOCK (by USPS) 8 INSTALLATION OF PARCEL DOOR ARROW LOCK (by USPS) 10 APPENDIX - APPENDIX-INDEPENDENT INSTALLATION WALL CONSTRUCTION 12 GENERAL INFORMATION AND ADVISORIES 4C MAILBOX SUITES CAUTION: HANDLING & TRANSPORTATION • LAY BOXES FLAT, DO NOT STAN
POSTAL PRODUCTS 500 W. OKLAHOMA AVE.
PARCEL ONLY UNIT FUNCTIONALITY AND INSTALLATION INFORMATION 4C MAILBOX SUITES (PARCEL ONLY UNIT) 1. PREPARING FOR INSTALLATION: (PARCEL ONLY UNITS) WHILE LOOKING AT THE BACK OF THE UNIT, SLIDE AND HOLD THE LATCH PLATE UP PAST THE LATCH HOOK AS ILLUSTRATED. THE FRONT OF THE UNIT CAN NOW BE OPENED TO GAIN ACCESS TO MOUNTING SCREW HOLES/SLOTS FOR INSTALLATION. REMOVE ALL HARDWARE LOCATED INSIDE THE UNIT AND SET ASIDE.
PARCEL ONLY UNIT FUNCTIONALITY AND INSTALLATION INFORMATION CONTINUED SLIDE LOCK SLOT N1029075 LATCH HOOK SLIDING LATCH PLATE N1029074 2 1 SLIDING LATCH PLATE FRONT OF UNIT BACK OF UNIT N1029085 - STD4C-118 REV 3 POSTAL PRODUCTS 500 W. OKLAHOMA AVE.
INDEPENDENT INSTALLATION 4C MAILBOX SUITES (ALL UNITS) 1. PLACE 4C UNIT IN OPENING UNTIL INTEGRATED TRIM IS FLUSH WITH WALL BOARD. SEE PAGE 4 (PARCEL ONLY) FOR ADDITIONAL INSTALLATION INFORMATION. NOTE: ONLY FRONT LOADING UNITS HAVE A HOLD OPEN ARM. THEREFORE, WHEN INSTALLING A PARCEL ONLY UNIT, YOU MAY IGNORE ALL REFERENCES TO HOLD OPEN ARM(S) IN THE REMAINDER OF THE TEXT. 2.
INDEPENDENT INSTALLATION CONTINUED TYPICAL WALL MOUNTING OUTER FRAME MEMBER INTEGRATED TRIM 1 2 N1029076 WARNING: INSTALLATION • 4C UNITS ARE FRONT-HEAVY. DO NOT STAND ON END WITHOUT SUPPORT TO PREVENT TIPPING. MAILBOXES MAY TIP OUT OF ROUGH OPENING UNTIL SECURED, POSSIBLY RESULTING IN THE MAILBOX COLLIDING WITH A PERSON AND CAUSING SERIOUS INJURY. • 4C UNITS ARE VERY FRONT-HEAVY WITH MASTER LOADING DOORS OPEN. UNITS MUST BE BRACED OR HELD IN PLACE UNTIL SECURED TO FRAMING.
LOCK REPLACEMENT 4C MAILBOX SUITES (ALL UNITS) 2 1 1. REMOVE THE THREE ONE-WAY SCREWS FROM THE CAM LINK COVER TO EXPOSE THE LOCK ASSEMBLY. 2. REMOVE THE 910 NUT FROM THE 910A LOCK. 4 3 3. REMOVE THE CAM LOCK FROM THE 910A LOCK. YOU DO NOT NEED TO DISCONNECT THE CAM LINK ASSEMBLY. 4. TAP THE LOCK RETAINING CLIP FREE FROM THE 910A LOCK WITH A FLAT BLADE SCREWDRIVER AND MALLET. √ 5. REMOVE THE LOCK AND REPLACE. REVERSE THE STEPS IN ORDER TO INSTALL THE NEW 910A LOCK.
INSTALLATION OF COLLECTION DOOR ARROW LOCK 4C MAILBOX SUITES (FRONT LOAD ONLY) ARROW LOCK INSTALLED BY U.S. POSTAL SERVICE PERSONNEL ONLY. CONTACT YOUR LOCAL POST OFFICE TO ARRANGE INSTALLATION OF ARROW LOCK. 1. INSERT ARROW LOCK INTO N1029078 PLATE ASSY.-HS ARROW LOCK AS SHOWN. 2. WITH THE COLLECTION DOOR OPEN, SLIDE N1029078 PLATE ASSY.HS ARROW LOCK WITH ARROW LOCK ONTO THE COLLECTION DOOR BOLTS. 3. INSTALL N1029079 PLATE-LOCK SUPPORT AS ORIENTED IN THE ILLUSTRATION. 4.
INSTALLATION OF COLLECTION DOOR ARROW LOCK FOR USPS PERSONNEL ONLY (CONTINUED) N1029078 ARROW LOCK (PROVIDED BY USPS) 1 COLLECTION DOOR 2 N1029079 3 4 N1029080 N1029085 - STD4C-118 REV 3 10 PHONE: 800-229-4500 • FAX: 800-570-0007 POSTAL PRODUCTS
PARCEL DOOR ARROW LOCK INSTALLATION 4C MAILBOX SUITES (FRONT LOAD ONLY) ARROW LOCK INSTALLED BY U.S. POSTAL SERVICE PERSONNEL ONLY. CONTACT YOUR LOCAL POST OFFICE TO ARRANGE INSTALLATION OF ARROW LOCK. 1. OPEN PARCEL DOOR AND LOCK PARCEL DOOR CUSTOMER LOCK. NOTE: PARCEL DOOR CUSTOMER LOCK IS IN LOCKED POSITION WHEN KEY CAN BE REMOVED. 2. SLIDE N1029081 PARCEL DOOR, LOCK STIFFENER ONTO THE PARCEL DOOR BOLTS, AS ORIENTED IN THE ILLUSTRATION. 3.
PARCEL DOOR ARROW LOCK INSTALLATION FOR USPS PERSONNEL ONLY (CONTINUED) 1 2 3 N1029081 4 ARROW LOCK (PROVIDED BY USPS) N1029084 N1029083 N1029082 4 N1029084 N1029082 N1029085 - STD4C-118 REV 3 12 PHONE: 800-229-4500 • FAX: 800-570-0007 POSTAL PRODUCTS
SUGGESTIONS OF INDEPENDENT INSTALLATION WALL CONSTRUCTION 4C MAILBOX SUITES (FRONT LOAD ONLY) 4C UNITS FEATURE TRIM DESIGNED TO MATE (NO GAP BETWEEN UNITS) FLUSH WHEN A SINGLE STUD IS USED BETWEEN UNITS WALL MOUNTING SHOULD CONSIST OF A LAMINATION OF TWO STUDS ON OUTSIDE OF EVERY UNIT 17” MINIMUM SINGLE COLUMN OPENING DOUBLE COLUMN OPENING NOTES: 1. ALL WALL MOUNTING MEMBERS ARE MADE FROM WOOD 2"x 4" (STUDS). 2.