User's Manual

Power-One Italy SpA
Monitoring & Control
xxx
Doc. Title
Revision
Page
Cellular Card Block Diagram
A-4
4 (6)
CONFIDENTIAL COPYRIGHT 2015, 2016 ABB ALL RIGHT RESERVED
Page 4 of 6
Local monitoring
Wirelessly allowed via any Wi-Fi
®
or Eth. device connecting the
integrated WUI
Remote monitoring
Plant Portfolio Manager
®
/ Plant Viewer
TM
Communications Protocol
LAN/WAN Protocols
HTTPS, DHCP, NTP, SSL, SSH, XML, Modbus TCP (SunSpec)
Meter specification
Enclosure
Meter integrated in the same box of the cellular.
It can be sold as a standalone product
External interface
Isolated 485 (present only when meter is sold as a standalone
product)
LED interface
3 LEDs (pulse/kW, pulse/kVar, diagnostic)
Data logging specifications
Data Sampling rate
High Frequency data sampling (less than 1 minute average)
Local data storage
Log data for 30 days based on 15-minute intervals
Upgradeability
Remotely via Aurora Vision
®
Plant Management Platform / Locally
via WUI
Meter data logging as
standalone
None
Advanced functionalities
Remote O&M operations
Inverter parameters setting / Inverter firmware upgrade
Smart Grid functionalities
Grid Control power-management enabled
Electrical specifications
DC Power consumption
~ 2W; max 5W during modem activity
Environmental parameters
Ambient temperature range
[-40; +85] °C; it can be reduced depending on the modem
Environmental protection
IP 20 (IP65 in the inverter switch box)
Relative humidity
< 85% Non-condensing
Mechanical parameters (per unit)
Dimensions (H x W x D)
86 mm x 128.14 mm x 40 mm
Weight
~ 40g
Advanced functionalities
Remote O&M operations
Inverter’s parameters setting / Inverter’s firmware upgrade
Smart Grid functionalities
Grid Control power-management enabled
Compliance
Marking
FCC/Wi-Fi Certified
TM
Emissions
FCC CFR47, Part15, Subpart C.
This device complies with part 15 of the FCC Rules.
Operation is subject to the following two conditions: (1) this device
may not cause harmful interference, and (2) this device must accept
any interference received, including interference that may cause
undesired operation.
CISPR 22; EN 55022 Conducted and radiated emission