Service Manual User Manual

12
Membrane Error
– In the event that one of the control panel buttons sends a constant
signal to the UPM, the program will recognize that the membrane is defective and
display this error code (see Section 6.9 Push Button Membrane).
Please have the “Error Code” information and serial number of the machine available
when calling Power Soak Systems for telephone assistance (1-800-444-9624). The
machine serial number will be used to identify the configuration of the machine. The
serial number is 5-6 digits long and located on the identification tag which is on the
lower corner of the wash tank close to the control panel enclosure.
Note: There are periods of unstable power from the incoming power source that can
cause a false error. Turning the electrical power off and on can reset the program if it is
a power source fluctuation that caused the error. Locate the wall mounted circuit
breaker box, turn the circuit breaker for the Power Soak machine off, pause for 15
seconds, turn the circuit breaker back on, and then check to see if the error code has
cleared.
5.6 Blue Wash Tank Light
Solid Illumination – “CHANGE WASH SOLUTION” the
wash cycle will be stopped until the wash tank is
completely drained and refilled.
Slow to Fast Flashing – wash solution life is expiring, 15
minute warning prior to solid illumination.
Flashing with Green Status light – occurs when tank is filling with water indicating near
full, rapid flashing indicates that the tank is full (NOTE: the fill indication feature is an
option that must be selected in the UPM settings, see programming manual 37193.)
5.7 Red Sanitizer Tank Light
Solid Illumination – “FILL SANITIZER TANK” – sanitizer tank
must be filled to the waterline.
OR
Solid Illumination – “CHANGE SANITIZE SOLUTION” – After
two hours, the sanitizer tank must be drained and refilled.
Slow to Fast Flashing – wash solution life is expiring, 15 minute warning prior to solid
illumination.
Flashing with Green Beacon light – occurs when tank is filling with water indicating near
full, rapid flashing indicates that the tank is full (NOTE: the fill indication feature is an
option that must be selected in the UPM settings, see programming manual 37193.)