The column under P-BUS indicates the PowerBUS channel number. CH1 - CH16
are proportional channels, while CH17 and CH18 are switched channels. At a later
stage these numbers are crucial when we move on to programming the servo or
the PowerBUS adapter.
The OUTPUT is user-variable; here you determine which PowerBox output (A - X)
is assigned to the selected BUS channel (1 - 18).
The FUNCTION column shows which function is assigned to the output you have
selected. This provides a clear overview of the functions which are already assi-
gned to the bus.
In our example the gyro function GY AILERON A has been assigned to outputs G
and H, so that these two functions can be ne-tuned later using the ServoMatch
function. At the PowerBUS they have been assigned to channel numbers 2 and 3.
b) Procedure for setting up the PWM Adapter
Our function GY AILERON A is now assigned to bus channels 2 and 3. The next
stage must be to inform the PowerBUS to PWM Adapter (description under 2c)
which bus channel is to be generated at which of the four sockets (servo 1 - 4).