USB Power Output
DC output voltage 5V DC, 2 ports shared
2.4 Amps output
DC Power Specifications
DC input voltage range 11V to 15V DC
Battery drain with no AC load 0.6A
Low battery shutdown point (nominal) 10.5±0.3V DC
High battery shutdown point (nominal) 15.5±0.5V DC
Fuse 35A x3 blade fuse
Efficiency (maximum) 85%
Physical Specifications
Ambient operating temperature range 32°F to 104°F
TROUBLESHOOTING
Problem Cause Solution
No power, no
indicator
Battery is defective. Replace battery.
Blown fuse. Check and replace fuse.
Loose cable connections. Check the connection to the
battery. Tighten as required.
The red LED
indicator
illuminates
The actual output is higher
than rated power of inverter,
Overload protection has
occurred.
Reduce load to have the
actual output lower than
rated power of inverter.
The actual output is less
than rated power, but high
starting surge has caused
overload shutdown.
Use a product with starting
surge power within the
inverter’s capability.
The voltage input is too low. Charge the battery.
Inverter is overheated due to
poor ventilation and has shut
down.
Disconnect the inverter from
battery or DC socket and
allow to be cooled for 15
minutes. Please ensure to
remove objects covering
the unit.