Full Product Manual

THE SELF PROTECTION OF YOUR INVERTER
Type Possible cause
How do you know
if the protection is
activated?
Solution Remarks
Current
overload
If the output
power exceeds
the rated output
power 10 to 15%.
Fault indicator LED
will light up and the
inverter will
automatically shut off
Remove all appliances and
turn off the unit by the
ON/OFF switch. Then turn on
the unit again. Use smaller
power consumption
appliances.
Input low
voltage
Input voltage
lower than 10.5V.
Remove all appliances and
turn off the unit by the
ON/OFF switch. Recharge
the battery.
Input high
voltage
Input voltage
higher than 15V.
Remove all appliances and
turn off the unit by the
ON/OFF switch. Check the
battery voltage, make sure it
is within 11V to 15V.
Although the inverter has
protection against over
load, it may still damage
the inverter if the input
voltage exceeds 16V.
Over
temperature
The PCB
temperature is
around 230°F.
Remove all appliances and
turn off the unit by the
ON/OFF switch. Cool down
for 15 minutes before turning
on again.
Please ensure there is
ventilation in the
surrounding environment.