56 Configuring the iDRAC6 Using the Web Interface
Configuring Platform Events
Platform event configuration provides a mechanism for configuring the
iDRAC6 to perform selected actions on certain event messages. The actions
include no action, reboot system, power cycle system, power off system,
and generate an alert (Platform Event Trap [PET] and/or e-mail).
The filterable platform events are listed in Table 4-9.
.
Table 4-9. Platform Event Filters
Index Platform Event
1Fan Critical Assert
2 Battery Warning Assert
3 Battery Critical Assert
4 Voltage Critical Assert
5 Temperature Warning Assert
6 Temperature Critical Assert
7 Intrusion Critical Assert
8 Redundancy Degraded
9 Redundancy Lost
10 Processor Warning Assert
11 Processor Critical Assert
12 Processor Absent Critical Assert
13 Power Supply Warning Assert
14 Power Supply Critical Assert
15 Power Supply Absent Critical Assert
16 Event Log Critical Assert
17 Watchdog Critical Assert
18 System Power Warning Assert
19 System Power Critical Assert
20 Removable Flash Media Absent Informational Assert
21 Removable Flash Media Critical Assert