Industrial Scroll Air Compressor System
Specicaon
General
The Powerex Scroll tank mounted system is designed to provide
clean, dry air for industrial applicaons where the quality of the
compressed air is crical. This package shall have V-belt drive/s, OSHA
compliant beltguard/s, safety relief valve, check valve/s, pressure
gauge and pressure switch/s.
Air Compressor System
The package shall include one or two oil-less scroll air compressor
and associated equipment, one ASME tank, and one oponal magnec
starter/alternang control panel. The only eld connecons required
will be system discharge, power connecon at the control panel
and dryer, and condensate drain connecon. The dryer and electric
drain require standard 115V outlet. All interconnecng piping and
wiring shall be included and operaonally tested prior to shipment. A
refrigerated air dryer system is oponal.
Oilless Scroll Compressor Pump
The compressor/s shall be belt driven oil-less rotary scroll single
stage, air-cooled oil-less construcon with absolutely no oil needed
for operaon. The rotary design shall not require any inlet or exhaust
valves and shall be rated for 100% connuous duty. Direct drive
compressors shall not be used. Tip seals shall be of a composite
PTFE material and be rated for 10,000 hours operaon or 5,000
hours if high pressure. Compressor bearings shall be external to the
air compression chamber and shall all be serviceable for extended
compressor life. Bearing maintenance shall not be required unl
10,000 run hours. Compressors with bearings that are not accessible
for service have a limited life span and shall not be accepted.
Compressors shall have an integral radial ow fan for cooling and shall
not require and addional electrical cooling fans. Each compressor
shall have an air-cooled aercooler.
Motor
Each compressor shall be belt driven by a 1750 RPM, ODP NEMA
construcon motor. OSHA approved belt guards shall be provided.
Motor shall not operate in the service factor. Oponal motors include
TEFC.
Air Receiver
The system shall include an ASME rated air receiver, rated for 200
PSI MAWP. The tank shall be equipped with a pressure gauge, safety
relief valve, discharge shut-o valve, and manual tank drain.
Oponal drain valves include: 1) 115V “No-loss” type automac
tank drain, 2) 115V automac solenoid mer drain, or 3) automac
oat style drain.
Air-cooled Aercooler
Air-cooled aercoolers shall be provided for each compressor and
shall be sized to provide an approach temperature of 20 degrees F.
Each unit shall be constructed of copper tubing and shall be installed
on the tank.
Air Filter
The standard inlet lter screens directly into the pump inlet and is
a pleated element. Oponal items include threaded inlet housings for
remote piping.
Oponal Control Panel
Simplex
The system shall include a UL listed magnec starter in a NEMA 1
enclosure with full voltage motor starter with overload protecon.
Duplex
The system shall include a UL listed magnec starter in a NEMA 1
enclosure with full voltage motor starter with overload protecon,
an alternator, 120 volt transformer, fused primary and secondary
circuits, elapsed me indicators, and maintenance switch (le/auto/
right). Control panels shall be UL 508A listed and labeled.
Oponal Refrigerant Air Dryer
The Powerex air drying system shall be tank mounted with
compressor, and shall provide air at a 35-38 degree F pressure dew
point. The refrigerated compressed air dryer is non-cycling, direct
expansion, using R-134a refrigerant. A constant pressure expansion
valve is provided to maintain a 38 degree F evaporator temperature.
The dryer is self-regulang for large load swings, and includes a 3
micron lter/separator with automac condensate drain. Refrigerated
dryers are to be powered from a separate supply, not through the
compressor controls. Opon also includes a .01 micron aer lter, a
pressure regulator and an installed automac solenoid mer drain.
Available Opons
Motor opons
TEFC
Air Receiver opons
30, 60, 80, 120 gal. (unit specic)
Electric drain
No loss drain
FDA approved tank lining
Control Panel opons
NEMA 4/12
High temperature
Inlet lter opons
Threaded for remote inlet
Refrigerant air dryer
Motor slide base (per motor)
50 Hz operaon
High Pressure (145 psig operaon)