Operating Instructions
CelloTrack Solar Overview
CelloTrack Solar Overview.docx Page 13 of 31
Copyright © 2019 by Pointer Telocation, Ltd.
GNSS is in GYRO mode
(only for compatible
models)
Note: To save energy, the COMM LED performs only 10 indications cycles (total time
120 seconds) upon unit activation and/or upon unit reset, and is then shut off.
3.2 User Features
3.2.1 Activation
When the unit is not active, upon pressing the front button for 5 seconds (long press),
the unit is activated. The SYS LED lights for 5 seconds in
Green, to indicate that the
unit is active. The COMM LED performs 10 GSM/GPS indication cycles, and then is shut
off.
Note that after battery replacement, the unit is automatically activated, i.e. with no
need of activation by button as described above. After automatic activation, the SYS
LED behaves as described above.
------------------------------------------------------------------------------------------------
NOTE: Consecutive presses are ignored, if started before the SYS LED indication of
the previous press/sequence ended.
------------------------------------------------------------------------------------------------
3.2.2 De-Activation
When the unit is active, upon pressing the front button for 5 seconds (long press), the
unit is de-activated. The SYS LED shall light for 5 seconds in
Red, to indicate that the
unit is not active. For enabled logged or distress events, the de-activation is postponed
until the events are transmitted (or until Modem Max On Time expiration). In the
postponed time, the SYS LED blinks (200msec on every 1 second) in Red.
------------------------------------------------------------------------------------------------
NOTE: Consecutive presses are ignored, if started before the SYS LED indication of
the previous press/sequence ended.
------------------------------------------------------------------------------------------------
3.2.3 Panic/Distress
When the unit is active, upon pressing the front button for a period of between 0 and 5
seconds (short press), a panic/distress press is recognized. The SYS LED then reflects
the battery SOH (State of Health):
If the SOH is above the preprogrammed minimum - the SYS LED lights for 2
seconds in Green.
If the SOH is below (or equal to) the preprogrammed minimum - the SYS LED
lights for 2 seconds in
Red.