Product Manual

Operation (cont’d)
25
2. Preparing for Operation
Position
generator
Position generator in accordance with the instructions given in “Installation &
Initial Set-up, Step 4: Select a Suitable Site” of this manual.
Operate outside only, on dry, level ground with adequate clearance and ventilation.
WARNING: Carbon monoxide poisoning hazard
Generators give off carbon monoxide exhaust, a poisonous gas that can kill. You
CANNOT smell it, see it, or taste it. ONLY run generator OUTDOORS and away
from air intakes. NEVER run generator inside any enclosed or semi-enclosed
spaces, including homes, garages, basements, sheds, boxes, pick-up truck beds,
RVs, or boats. These spaces can trap poisonous gases, EVEN if you run a fan or
open windows. Carbon monoxide exhaust is given off whether you are using
gasoline, natural gas, or propane to power the generator.
Ground
generator
Make sure the generator is grounded in accordance with instruction given in
“Installation & Initial Set-up, Step 5: Grounding the Generator” of this manual.
WARNING: Electric shock hazard
Always ensure generator is properly grounded to prevent electrical shock.
Perform
scheduled
maintenance as
needed
Make sure that any regular maintenance has been performed as prescribed in this
manual in the “Maintenance & Repair” section.
1. Refer to the engine section of this manual for engine maintenance instructions.
2. Make sure battery is charged. Charge as needed according to your battery
manufacturer’s instructions.
Check/add oil
Check the oil level and add oil as needed.
Insert dipstick into the oil fill hole, completely thread in and check oil level.
Using a funnel, add oil up to the “H” high mark on the dipstick with recommended oil.
(See engine section for oil type and capacity, and more detailed oil check/fill instructions.)
WARNING: Burn hazard
Never open oil port while engine is running. Hot oil can spray over face and body.
˙
Notes:
Low oil shutdown feature prevents the generator from starting without sufficient oil.
Engine is shipped without oil. You must add oil before first use.
IMPORTANT:
Under long, continuous-run operating conditions, be prepared to:
Check engine oil level every time you refuel the engine.
Change oil after the first 20 operating hours, and at least every 100 operating
hours thereafter, or as directed in engine section of this manual.